PLASMA-LEVELS OF MAIN GRANULOCYTE COMPONENTS DURING HEMODIALYSIS - COMPARISON OF NEW AND REUSED DIALYZERS

被引:28
作者
HORL, WH
FEINSTEIN, EI
WANNER, C
FRISCHMUTH, N
GOSELE, A
MASSRY, SG
机构
[1] UNIV SO CALIF,SCH MED,DIV NEPHROL,2025 ZONAL AVE,LOS ANGELES,CA 90033
[2] UNIV SO CALIF,SCH MED,DEPT MED,LOS ANGELES,CA 90033
[3] UNIV FREIBURG,DIV NEPHROL,W-7800 FREIBURG,GERMANY
关键词
Complement activation; Cuprophane; Dialyzer; Granulocyte; Hemodialysis; Neutrophil degranulation;
D O I
10.1159/000168054
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Complement activation occurs during hemodialysis, and its intensity depends on the type of dialyzer and whether it is new or reused. Neutrophil degranulation also occurs during hemodialysis with release of lactoferrin, myeloperoxidase and elastase. However, it is unclear whether this event is induced by complement activation and whether it is attenuated by reuse. We examined complement activation and neutrophil degranulation during 10 consecutive hemodialysesusing the same cuprophane dialyzer. Also the effect of rinsing the latter with 25% human albumin was studied. The rise in plasma C3a and C5a was markedly higher (p < 0.01) during the first than the second use. Plasma levels of lactoferrin and myeloperoxidase increased significantly (p < 0.01) during the first use, and levels were not affected by reuse. In contrast, plasma elastase increased with the first use and decreased with each subsequent use.Treatment of the dialyzer with albumin did not affect the magnitude of rise in plasma levels of C3a or lactoferrin butwas associated with a significant reduction in plasma elastase. The data show that neutrophil degranulation is not dependent on complement activation and that the two processes could be dissociated. © 1990 S. Karger AG, Basel.
引用
收藏
页码:53 / 57
页数:5
相关论文
共 18 条
[1]  
Aljama P, 1978, Proc Eur Dial Transplant Assoc, V15, P144
[2]   COMPLEMENT ACTIVATION DURING HEMODIALYSIS - CLINICAL OBSERVATIONS, PROPOSED MECHANISMS, AND THEORETICAL IMPLICATIONS [J].
CHENOWETH, DE .
ARTIFICIAL ORGANS, 1984, 8 (03) :281-287
[3]   ANAPHYLATOXIN FORMATION DURING HEMODIALYSIS - COMPARISON OF NEW AND RE-USED DIALYZERS [J].
CHENOWETH, DE ;
CHEUNG, AK ;
WARD, DM ;
HENDERSON, LW .
KIDNEY INTERNATIONAL, 1983, 24 (06) :770-774
[4]   ANAPHYLATOXIN FORMATION DURING HEMODIALYSIS - EFFECTS OF DIFFERENT DIALYZER MEMBRANES [J].
CHENOWETH, DE ;
CHEUNG, AK ;
HENDERSON, LW .
KIDNEY INTERNATIONAL, 1983, 24 (06) :764-769
[5]   HEMODIALYSIS LEUKOPENIA - PULMONARY VASCULAR LEUKOSTASIS RESULTING FROM COMPLEMENT ACTIVATION BY DIALYZER CELLOPHANE MEMBRANES [J].
CRADDOCK, PR ;
FEHR, J ;
DALMASSO, AP ;
BRIGHAM, KL ;
JACOB, HS .
JOURNAL OF CLINICAL INVESTIGATION, 1977, 59 (05) :879-888
[6]  
CRADDOCK PR, 1977, NEW ENGL J MED, V296, P760
[7]   BIOCOMPATIBILITY OF DIALYSIS MEMBRANES - EFFECTS OF CHRONIC COMPLEMENT ACTIVATION [J].
HAKIM, RM ;
FEARON, DT ;
LAZARUS, JM .
KIDNEY INTERNATIONAL, 1984, 26 (02) :194-200
[8]  
HAKIM RM, 1980, T AM SOC ART INT ORG, V26, P159
[9]  
HEIDLAND A, 1983, KIDNEY INT S16, V24, P27
[10]   EFFECT OF DIFFERENT DIALYZERS ON PROTEINASES AND PROTEINASE-INHIBITORS DURING HEMODIALYSIS [J].
HORL, WH ;
SCHAEFER, RM ;
HEIDLAND, A .
AMERICAN JOURNAL OF NEPHROLOGY, 1985, 5 (05) :320-326