ANALYSIS OF THE UNCERTAINTIES INVOLVED IN THE REALIZATION OF A SPECTRAL IRRADIANCE SCALE IN THE INFRARED AT THE NRC

被引:5
作者
BOIVIN, LP [1 ]
GAERTNER, AA [1 ]
机构
[1] NATL RES COUNCIL CANADA, INST NATL MEASUREMENT STAND, OTTAWA K1A 0R6, ONTARIO, CANADA
关键词
D O I
10.1088/0026-1394/28/3/005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new spectral irradiance scale in the near-infrared was realized at the NRC in 1989-1990. Electrical-substitution absolute radiometers were used in conjunction with interference filters to calibrate FEL and NPL/GEC tungsten halogen lamps in the spectral range 700 nm to 1 600 nm. This paper briefly reviews the method used and presents a detailed analysis of the theoretical and measurement uncertainties involved. Results of the measurements are also discussed briefly.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 4 条
  • [1] CALIBRATION OF INCANDESCENT LAMPS FOR SPECTRAL IRRADIANCE BY MEANS OF ABSOLUTE RADIOMETERS
    BOIVIN, LP
    [J]. APPLIED OPTICS, 1980, 19 (16): : 2771 - 2780
  • [2] BOIVIN LP, 1989, I PHYS C SER, V92, P81
  • [3] BOIVIN LP, 1989, ABSOLUTE RADIOMETRY, P170
  • [4] THE NBS SCALE OF SPECTRAL IRRADIANCE
    WALKER, JH
    SAUNDERS, RD
    JACKSON, JK
    MCSPARRON, DA
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1988, 93 (01): : 7 - 20