A RETROSPECTIVE ANALYSIS OF INFRAINGUINAL ARTERIAL RECONSTRUCTION - 3 YEAR PATENCY RATES

被引:8
作者
BRUMBY, SA [1 ]
PETRUCCO, MF [1 ]
WALSH, JA [1 ]
BOND, MJ [1 ]
机构
[1] FLINDERS UNIV,MED CTR,VASC SURG UNIT,BEDFORD PK,SA 5042,AUSTRALIA
来源
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY | 1992年 / 62卷 / 04期
关键词
AUTOGENOUS SAPHENOUS VEIN; INFRAINGUINAL ARTERIAL RECONSTRUCTION; INTERPOSITION VEIN CUFF TECHNIQUE FOR ANASTOMOSIS; POLYTETRAFLUOROETHYLENE ARTERIAL SUBSTITUTE; 3 YEAR GRAFT PATENCY;
D O I
10.1111/j.1445-2197.1992.tb07551.x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Primary infra-inguinal arterial reconstructions were reviewed for primary patency and outcome of thrombosis in 144 patients. Distal anastomoses in these patients were to the popliteal artery and were above the knee in 63, below the knee in 53 and at the tibial level in 28. The treatment used was: polytetrafluoroethylene (PTFE) in 33 cases, PTFE with an interposition vein cuff in 29 cases, autogenous saphenous vein (ASV) in situ in 47 cases, and reversed technique in 26 cases. Life table analysis showed a 59% overall primary patency at 3 years. Patency rates of above knee anastomoses (65%) and below knee (61%) were statistically different from the tibial anastomoses (42%, P = 0.005). In both above and below knee popliteal anastomoses there was a statistically significant difference in the patency of ASV and the PTFE/vein cuff technique (P = 0.0006) but there was no difference between ASV and PTFE. There was no difference in patency rates for the various types of grafts with tibial anastomoses. Data were analysed at 3 years, taking into account the variables of smoking, diabetes or indications for surgery respectively and no difference was found in patency. The number and calibre of the run-off vessels did not influence patency significantly, hence anastomosis to any good quality vessel regardless of run-off is recommended. The poor results with the interposition vein cuff technique are unexplained but this study suggests that the technique should be reserved for anastomoses below the popliteal artery.
引用
收藏
页码:256 / 260
页数:5
相关论文
共 14 条
[1]  
Kent K.C., Whittmore A.D., Mannick J.A., Short‐term and mid‐term results of an all autogenous tissue policy for infra‐inguinal reconstruction, J. Vasc. Surg., 9, pp. 107-114, (1989)
[2]  
Rosenbloom M.S., Walsh J.J., Schuler J.J., Et al., Long‐term results of infragenicular bypasses with autogenous vein originating from the distal superficial femoral and popliteal arteries, J. Vasc. Surg., 7, pp. 691-696, (1988)
[3]  
Simone S.T., Diebner B., Safi A.R., Et al., Comparative review of early and intermediate patency rates of polytetrafluoroethylene and autogenous saphenous vein grafts for lower extremity ischaemia, Surgery, 90, pp. 991-999, (1981)
[4]  
Yeager R.A., Hobson R.W., Jamil Z., Et al., Differential patency and limb salvage for polytetrafluoroethylene and autogenous saphenous vein in severe lower extremity ischaemia, Surgery, 91, pp. 99-103, (1982)
[5]  
Sterpetti A.V., Schultz R.D., Feldhaus R.J., Peetz D.J., Seven year experience with polytetrafluomethylene as above knee femoroppliteal bypass graft, J. Vasc. Surg., 2, pp. 907-911, (1985)
[6]  
Veith F.J., Gupta S.K., Ascer E., Et al., Six year prospective multicenter randomized comparison of autologous saphenous vein and expanded polytetrafluoroethylene grafts in infra‐inguinal arterial reconstructions, J. Vasc. Surg., 3, pp. 104-114, (1986)
[7]  
Flinn W.R., Rohrer M.J., Yao J.S.T., McCarthy W.J., Fahey V.A., Bergan J.J., Improved long‐term patency of infragenicular polytetrafluoroethylene grafts, J. Vasc. Surg., 7, pp. 685-690, (1988)
[8]  
Whittmore A.D., Kent K.C., Donaldson M.C., Couch N.P., Mannick J.A., What is the proper role of polytetrafluoroethylene grafts in infrainguinal reconstruction, J. Vasc. Surg., 10, pp. 299-305, (1989)
[9]  
Miller J.H., Foreman R.K., Ferguson L., Faris I., Interposition vein cuff for anastomosis of prosthesis to small artery, Aust. N.Z. J. Surg., 54, pp. 283-285, (1984)
[10]  
SPSS‐X User's Guide, (1986)