TECHNICAL FAILURE OF BILIARY METAL STENT DEPLOYMENT IN A SERIES OF 116 APPLICATIONS

被引:38
作者
BETHGE, N
WAGNER, HJ
KNYRIM, K
ZIMMERMANN, HB
STARCK, E
PAUSCH, J
VAKIL, N
机构
[1] HOSP NEUKOLLN,DEPT INTERNAL MED 4,BERLIN,GERMANY
[2] MUNICIPAL HOSP KASSEL,DEPT RADIOL,KASSEL,GERMANY
[3] MUNICIPAL HOSP KASSEL,DEPT INTERNAL MED 1,KASSEL,GERMANY
[4] HOSP E VON BERGMANN,DEPT RADIOL,POTSDAM,GERMANY
[5] UNIV ROCHESTER,ROCHESTER,NY 14627
关键词
D O I
10.1055/s-2007-1010506
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Biliary metal stents are thought to offer improved longterm palliation of malignant biliary obstruction due to a lower incidence of migration and clogging. Placement of these stents is technically more complicated than that of plastic endoprostheses and requires two experienced physicians. We report the incidence and reasons for apparent malfunction of expandable metal stent deployment (Wallstents(R) and Strecker(R) stents). In 116 applications of 82 Wallstents(R) (endoscopic approach: n = 33, transhepatic approach: n = 49), we observed 19 cases of stent malfunction due to technical problems of stent delivery. In 13 cases (15.8 %), the restraining membrane of the Wallstent(R) could not be retracted sufficiently to deliver the stent. There were 6 (17.6 %) failures in 34 cases of Strecker(R) stent deployment. In 3 cases, we noted difficult balloon removal, including avulsion of the balloon catheter shaft within the endoscope during attempted baloon removal in one case. In one case, the Strecker(R) stent could only be released partially, requiring subsequent endoscopic extraction. In two patients, only partial expansion of one end of the Strecker(R) stent could be achieved. Given the significant malfunction rate of expandable metal stents during stent delivery, further improvements in the delivery system of the metal stents are required.
引用
收藏
页码:395 / 400
页数:6
相关论文
共 8 条
  • [1] SELF-EXPANDABLE STAINLESS-STEEL ENDOPROSTHESES FOR TREATMENT OF MALIGNANT BILE-DUCT OBSTRUCTION
    ADAM, A
    CHETTY, N
    RODDIE, M
    YEUNG, E
    BENJAMIN, IS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (02) : 321 - 325
  • [2] SELF-EXPANDABLE STAINLESS-STEEL BRAIDED ENDOPROSTHESIS FOR BILIARY STRICTURES
    GILLAMS, A
    DICK, R
    DOOLEY, JS
    WALLSTEN, H
    ELDIN, A
    [J]. RADIOLOGY, 1990, 174 (01) : 137 - 140
  • [3] ENDOSCOPIC PLACEMENT OF EXPANDABLE METAL STENTS FOR BILIARY STRICTURES - A PRELIMINARY-REPORT ON EXPERIENCE WITH 33 PATIENTS
    HUIBREGTSE, K
    CHENG, J
    COENE, PPLO
    FOCKENS, P
    TYTGAT, GNJ
    [J]. ENDOSCOPY, 1989, 21 (06) : 280 - 282
  • [4] HILAR MALIGNANCY - TREATMENT WITH AN EXPANDABLE METALLIC TRANSHEPATIC BILIARY STENT
    LABERGE, JM
    DOHERTY, M
    GORDON, RL
    RING, EJ
    [J]. RADIOLOGY, 1990, 177 (03) : 793 - 797
  • [5] MALIGNANT BILIARY OBSTRUCTION - PERCUTANEOUS USE OF SELF-EXPANDABLE STENTS
    LAMERIS, JS
    STOKER, J
    NIJS, HGT
    ZONDERLAND, HM
    TERPSTRA, OT
    VANBLANKENSTEIN, M
    SCHUTTE, HE
    [J]. RADIOLOGY, 1991, 179 (03) : 703 - 707
  • [6] SELF-EXPANDING BILIARY STENTS - PRELIMINARY CLINICAL-EXPERIENCE
    NEUHAUS, H
    HAGENMULLER, F
    CLASSEN, M
    [J]. ENDOSCOPY, 1989, 21 (05) : 225 - 228
  • [7] ENDOSCOPIC AND PERCUTANEOUS IMPLANTATION OF SELF-EXPANDING STENTS FOR BILIARY STENOSES
    NEUHAUS, H
    HAGENMULLER, F
    GRIEBEL, M
    ROTTER, M
    CLASSEN, M
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1990, 115 (35) : 1299 - 1306
  • [8] NEUHAUS N, 1991, GASTROINTEST ENDOSC, V37, P253