COMPARISON OF CONVENTIONAL AUTORADIOGRAPHY WITH A NEW DNA ENZYME-IMMUNOASSAY FOR THE DETECTION OF HEPATITIS-C VIRUS-POLYMERASE CHAIN-REACTION AMPLIFICATION PRODUCTS

被引:5
作者
FEUCHT, HH
ZOLLNER, B
LAUFS, R
机构
[1] Institut für Medizinische Mikrobiologie und Immunologie, Universitätsklinikum Eppendorf, 20246 Hamburg
关键词
HEPATITIS C VIRUS; POLYMERASE CHAIN REACTION; HYBRIDIZATION; MONOCLONAL ANTIBODY; DOUBLE-STRANDED DNA;
D O I
10.1016/0166-0934(95)00049-Z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The detection of HCV-PCR amplification products by DNA enzyme immunoassay (DEIA) was compared with conventional hybridization carried out with a P-32-labelled oligonucleotide probe. The detection limit of both methods was shown to be between 100 pg and 1 ng of amplicon. All serum samples of 40 HCV-seropositive patients were positive after PCR in autoradiography, but only 38 with the DEIA technique (sensitivity 95%). There were no false-positive reactions by either method. The advantage of the DEIA method was the fast and non-radioactive detection of HCV amplicons. DEIA combines the specificity of the hybridization event with the speed of an ELISA procedure and is suitable for HCV-PCR.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 9 条
[1]  
CHOMCZYNSKI P, 1987, ANAL BIOCHEM, V162, P156, DOI 10.1016/0003-2697(87)90021-2
[2]  
CUTHBERT JA, 1994, CLIN MICROBIOL REV, V7, P502
[3]   STUDY ON RELIABILITY OF COMMERCIALLY AVAILABLE HEPATITIS-C VIRUS-ANTIBODY TESTS [J].
FEUCHT, HH ;
ZOLLNER, B ;
POLYWKA, S ;
LAUFS, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (03) :620-624
[4]   CHARACTERIZATION OF THE TERMINAL REGIONS OF HEPATITIS-C VIRAL-RNA - IDENTIFICATION OF CONSERVED SEQUENCES IN THE 5' UNTRANSLATED REGION AND POLY(A) TAILS AT THE 3' END [J].
HAN, JH ;
SHYAMALA, V ;
RICHMAN, KH ;
BRAUER, MJ ;
IRVINE, B ;
URDEA, MS ;
TEKAMPOLSON, P ;
KUO, G ;
CHOO, QL ;
HOUGHTON, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1991, 88 (05) :1711-1715
[5]   AN ASSAY FOR CIRCULATING ANTIBODIES TO A MAJOR ETIOLOGIC VIRUS OF HUMAN NON-A, NON-B-HEPATITIS [J].
KUO, G ;
CHOO, QL ;
ALTER, HJ ;
GITNICK, GL ;
REDEKER, AG ;
PURCELL, RH ;
MIYAMURA, T ;
DIENSTAG, JL ;
ALTER, MJ ;
STEVENS, CE ;
TEGTMEIER, GE ;
BONINO, F ;
COLOMBO, M ;
LEE, WS ;
KUO, C ;
BERGER, K ;
SHUSTER, JR ;
OVERBY, LR ;
BRADLEY, DW ;
HOUGHTON, M .
SCIENCE, 1989, 244 (4902) :362-364
[6]   AVOIDING FALSE POSITIVES WITH PCR [J].
KWOK, S ;
HIGUCHI, R .
NATURE, 1989, 339 (6221) :237-238
[7]  
MANTERO G, 1991, CLIN CHEM, V37, P422
[8]   CLOSE CORRELATION BETWEEN HEPATITIS-C VIRUS SEROLOGY AND POLYMERASE CHAIN-REACTION IN CHRONICALLY INFECTED PATIENTS [J].
REUTER, D ;
POLYWKA, S ;
ISKE, L ;
FEUCHT, HH ;
LAUFS, R .
INFECTION, 1992, 20 (06) :320-323
[9]  
Sambrook J., 1989, MOL CLONING LAB MANU