COMPREHENSIVE 2-DIMENSIONAL GAS-CHROMATOGRAPHY USING AN ON-COLUMN THERMAL MODULATOR INTERFACE

被引:658
作者
LIU, ZY [1 ]
PHILLIPS, JB [1 ]
机构
[1] SO ILLINOIS UNIV,DEPT CHEM & BIOCHEM,CARBONDALE,IL 62901
关键词
11;
D O I
10.1093/chromsci/29.6.227
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A thermal desorption modulator prepared on an open-tubular gas chromatographic column continuously generates fast chromatograms sampled from a flowing stream. The output from a slower chromatographic column is a suitable sample stream. Taking the output from one gas chromatographic column as input to a second column through a thermal modulator then generates a set of high-speed chromatograms. One such secondary chromatogram is generated at each point in the primary chromatogram. When plotted in an appropriate two-dimensional form, this set of high-speed chromatograms becomes a comprehensive two-dimensional gas chromatogram. A sample first separated by one column is separated a second time by an independent column. All substances in the sample mixture pass through both columns. Two retention time measures characterize each sample substance. Each substance forms a peak on the two-dimensional plane at a location determined by the interaction of the substance with the two different stationary phases.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 11 条
[1]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :978-984
[2]   A NEW GAS SAMPLING DEVICE FOR GAS-CHROMATOGRAPHY [J].
DEANS, DR .
JOURNAL OF CHROMATOGRAPHY, 1984, 289 (APR) :43-51
[3]   CONCEPTS AND COMPARISONS IN MULTIDIMENSIONAL SEPARATION [J].
GIDDINGS, JC .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (05) :319-323
[4]   ANALYSIS OF FLUE-CURED TOBACCO ESSENTIAL OIL BY HYPHENATED ANALYTICAL TECHNIQUES [J].
GORDON, BM ;
UHRIG, MS ;
BORGERDING, MF ;
CHUNG, HL ;
COLEMAN, WM ;
ELDER, JF ;
GILES, JA ;
MOORE, DS ;
RIX, CE ;
WHITE, EL .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1988, 26 (04) :174-180
[5]  
HIMBERG K, 1989, J MICROCOLUMN SEP, V1, P271
[6]   ELECTRICALLY HEATED COLD TRAP INLET SYSTEM FOR COMPUTER-CONTROLLED HIGH-SPEED GAS-CHROMATOGRAPHY [J].
LANNING, LA ;
SACKS, RD ;
MOURADIAN, RF ;
LEVINE, SP ;
FOULKE, JA .
ANALYTICAL CHEMISTRY, 1988, 60 (18) :1994-1996
[7]  
Liu Z., 1990, J MICROCOLUMN SEP, V2, P33
[8]  
Liu Z, 1989, J MICROCOLUMN SEP, V1, P249
[9]  
Liu Z., 1989, J MICROCOLUMN SEP, V1, P159, DOI [10.1002/mcs.1220010310, DOI 10.1002/MCS.1220010310]
[10]   MULTIPLEX GAS-CHROMATOGRAPHY BY THERMAL MODULATION OF A FUSED-SILICA CAPILLARY COLUMN [J].
PHILLIPS, JB ;
LUU, DS ;
PAWLISZYN, JB ;
CARLE, GC .
ANALYTICAL CHEMISTRY, 1985, 57 (14) :2779-2787