MR TOMOGRAPHY OF FOCAL LIVER-LESIONS USING THE SUPERPARAMAGNETIC CONTRAST AGENT AMI-25 AT 1.5 TESLA

被引:9
作者
DUDA, SH
LANIADO, M
KOPP, AF
GRONEWALLER, E
AICHER, KP
PAVONE, P
JEHLE, E
CLAUSSEN, CD
机构
[1] UNIV ROMA LA SAPIENZA, RADIOL DIAGNOST ABT, ROME, ITALY
[2] EBERHARD KARLS UNIV TUBINGEN, ALLGEMEINCHIRURG ABT, TUBINGEN, GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1994年 / 160卷 / 01期
关键词
LIVER; MR STUDIES; CONTRAST ENHANCEMENT;
D O I
10.1055/s-2008-1032371
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Superparamagnetic iron oxide particles (AMI-25) were evaluated as a liver contrast agent in high-field MR imaging (1.5 T). 16 patients with up to 5 presumed focal liver lesions (liver metastases n = 8, HCC n = 5, Klatskin tumours n = 2, FNH n = 1) received 15 mu mol Fe/kg BW intravenously and were examined via standard T-1- and T-2-weighted spin-echo sequences. Quantitative image analysis showed a post-contrast increase of the contrast-to-noise ratio (C/N) from 1.6 to 7.4 on SE 2,500/15 images (p < .05). However, C/N was in the same range on plain SE 2,500/90 scans. Blind evaluation by two independent readers revealed that AMI-25-enhanced images did not provide a significantly increased number of lesions. Two patients reported minor, self-limited side-effects (flush, back pain). We conclude that in contrast to reports at mid-field MR imagers, the use of AMI-25 at 1.5 T does not significantly improve the detection of focal liver lesions on conventional SE images.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 16 条
[1]  
BACON BR, 1987, J LAB CLIN MED, V110, P164
[2]   HEPATIC MR IMAGING WITH MN-DPDP - SAFETY, IMAGE QUALITY, AND SENSITIVITY [J].
BERNARDINO, ME ;
YOUNG, SW ;
LEE, JKT ;
WEINREB, JC .
RADIOLOGY, 1992, 183 (01) :53-58
[3]  
BRASCH RC, 1992, RADIOLOGY, V183, P1
[4]   FERROMAGNETIC PARTICLES AS CONTRAST AGENTS FOR MAGNETIC-RESONANCE-IMAGING OF LIVER AND SPLEEN [J].
DIAS, MHM ;
LAUTERBUR, PC .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (02) :328-330
[5]   IRON-OXIDE ENHANCED MR-IMAGING OF THE LIVER AND SPLEEN - REVIEW OF THE 1ST-5 YEARS [J].
FERRUCCI, JT ;
STARK, DD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) :943-950
[6]  
HAGSPIEL KD, 1992, SMRM BOOK ABSTR, V2, P3222
[7]   CT AND MRI OF THE EPIGASTRIUM - IS THE MRI COMPETITIVE [J].
HAMM, B .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (01) :3-4
[8]  
HAMM B, 1993, INT KERNSPIN TOMOGRA
[9]  
HILLMAN RS, 1990, PHARMACOL BASIS THER, P1277
[10]   DETECTION OF LIVER METASTASES WITH SUPERPARAMAGNETIC IRON-OXIDE IN 15 PATIENTS - RESULTS OF MR IMAGING AT 1.5-T [J].
MARCHAL, G ;
VANHECKE, P ;
DEMAEREL, P ;
DECROP, E ;
KENNIS, C ;
BAERT, AL ;
VANDERSCHUEREN, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (04) :771-775