SUBAPONEUROTIC HEMORRHAGE IN THE 1990S - A 3-YEAR SURVEILLANCE

被引:39
作者
NG, PC
SIU, YK
LEWINDON, PJ
机构
[1] Department of Paediatrics, Prince of Wales Hospital
关键词
D O I
10.1111/j.1651-2227.1995.tb13826.x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
A 3-year survey of subaponeurotic haemorrhage (January 1991 to December 1993) in a tertiary referral centre in Hong Kong revealed that the incidence of this life-threatening condition was 6.4 per 1000 ventouse-associated deliveries, which is 60-fold more common than with other modes of childbirth. We highlight a lesser known phenomenon of marked male predominance (male to female ratio 8 : 1). Three of 18 (17%)infants with subaponeurotic haemorrhage died. Severe subaponeurotic haemorrhage with a decrease in venous haematocrit > 25% of the baseline value at birth and requiring urgent blood transfusion in the first 12 h, in association with significant birth asphyxia with arterial cord blood pH < 7.20 and 1-min Apgar score less than or equal to 3 were the most important risk factors for death. A worrying feature was the silent presentation of occult subaponeurotic haemorrhage in two of the fatal cases. Frequent monitoring of haematocrit, early and rapid restoration of blood volume and prompt commencement of cardiac inotropes are the keys to the management of this condition, which should be suspected in all ill newborn infants subjected to the ventouse applicator.
引用
收藏
页码:1065 / 1069
页数:5
相关论文
共 14 条
[1]   MASSIVE SUBAPONEUROTIC HAEMORRHAGE IN INFANTS BORN BY VACUUM EXTRACTION [J].
AHUJA, GL ;
WILLOUGHBY, ML ;
KERR, MM ;
HUTCHISON, JH .
BMJ-BRITISH MEDICAL JOURNAL, 1969, 3 (5673) :743-+
[2]  
BERKUS MD, 1985, OBSTET GYNECOL, V66, P503
[3]  
BOO N Y, 1990, SMJ Singapore Medical Journal, V31, P207
[4]  
BROEKHUIZEN FF, 1987, OBSTET GYNECOL, V69, P338
[5]   FOLLOW-UP OF BABIES DELIVERED IN A RANDOMIZED CONTROLLED COMPARISON OF VACUUM EXTRACTION AND FORCEPS DELIVERY [J].
CARMODY, F ;
GRANT, A ;
MUTCH, L ;
VACCA, A ;
CHALMERS, I .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1986, 65 (07) :763-766
[6]   THE OBSTETRIC VACUUM EXTRACTOR IS THE INSTRUMENT OF 1ST CHOICE FOR OPERATIVE VAGINAL DELIVERY [J].
CHALMERS, JA ;
CHALMERS, I .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1989, 96 (05) :505-506
[7]   A RANDOMIZED PROSPECTIVE-STUDY COMPARING DELIVERY WITH METAL AND SILICONE-RUBBER VACUUM EXTRACTOR CUPS [J].
CHENOY, R ;
JOHANSON, R .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1992, 99 (05) :360-363
[8]   VACUUM EXTRACTION, BONE INJURY AND NEONATAL SUBGALEAL BLEEDING [J].
GOVAERT, P ;
VANHAESEBROUCK, P ;
DEPRAETER, C ;
MOENS, K ;
LEROY, J .
EUROPEAN JOURNAL OF PEDIATRICS, 1992, 151 (07) :532-535
[9]   NEW DESIGN RIGID AND SOFT VACUUM EXTRACTOR CUPS - A PRELIMINARY COMPARISON OF TRACTION FORCES [J].
HOFMEYR, GJ ;
GOBETZ, L ;
SONNENDECKER, EWW ;
TURNER, MJ .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (08) :681-685
[10]   NORTH-STAFFORDSHIRE WIGAN ASSISTED DELIVERY TRIAL [J].
JOHANSON, R ;
PUSEY, J ;
LIVERA, N ;
JONES, P .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1989, 96 (05) :537-544