A BIORESORBABLE URETHRAL STENT - AN EXPERIMENTAL-STUDY

被引:92
作者
KEMPPAINEN, E
TALJA, M
RIIHELA, M
POHJONEN, T
TORMALA, P
ALFTHAN, O
机构
[1] KUOPIO UNIV HOSP,SURG CLIN,HELSINKI,FINLAND
[2] JORVI HOSP,DEPT PATHOL,HELSINKI,FINLAND
[3] TAMPERE UNIV TECHNOL,INST PLAST TECHNOL,SF-33101 TAMPERE 10,FINLAND
来源
UROLOGICAL RESEARCH | 1993年 / 21卷 / 03期
关键词
BIODEGRADABLE MATERIAL; EXPERIMENTAL STUDY; URETHRAL STENT; URETHRAL STRICTURE;
D O I
10.1007/BF00590042
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The aim of the present study was to examine the suitability of biodegradable polymers as materials for a urethral stent. A new urethral stent made of biodegradable self-reinforced poly-L-lactide (SR-PLLA) was implanted in 16 male rabbits after urethrotomy. Seven stents of stainless steel served as controls. The dimensions of the two types of stents were identical: length 15 mm, diameter 8.2 mm. The mechanical construction was a helical spiral. The SR-PLLA spiral was sustained with three microspirals, and the whole device was coated with DL-lactide to achieve an active initial tissue reaction and better tissue penetration. The SR-PLLA stent showed more favourable implantation properties than the steel one. Within 6 months all PLLA stents had implanted, and the tissue reaction around the stent material was minimal. The helical spiral of stainless steel induced a remarkable inflammatory reaction due to poor implantation properties. We suggest that biodegradable SR-PLLA is a promising material for a urethral stent to prevent re-stenosis of urethral strictures.
引用
收藏
页码:235 / 238
页数:4
相关论文
共 10 条
[1]  
ASHKEN MH, 1991, EUR UROL, V19, P181
[2]  
HOLMNIELSEN A, 1991, BR J UROL, V56, P308
[3]  
MILROY EJG, 1988, LANCET, V1, P1424
[4]   RECURRENT URETHRAL STRICTURE DISEASE MANAGED BY CLEAN INTERMITTENT SELF-CATHETERIZATION [J].
NEWMAN, LH ;
STONE, NN ;
CHIRCUS, JH ;
KRAMER, HC .
JOURNAL OF UROLOGY, 1990, 144 (05) :1142-1143
[5]   RECURRENCE OF URETHRAL STRICTURE AND LATE RESULTS AFTER OPTICAL URETHROTOMY - COMPARISON OF STRICTURES CAUSED BY TOXIC LATEX CATHETERS AND OTHER CAUSES [J].
PITKAMAKI, KK ;
TAMMELA, TLJ ;
KONTTURI, MJ .
SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1992, 26 (04) :327-331
[6]   ABSORBABLE MATERIALS IN ORTHOPEDIC-SURGERY [J].
ROKKANEN, PU .
ANNALS OF MEDICINE, 1991, 23 (02) :109-115
[7]   SELF-EXPANDING ENDOVASCULAR PROSTHESIS - AN EXPERIMENTAL-STUDY [J].
ROUSSEAU, H ;
PUEL, J ;
JOFFRE, F ;
SIGWART, U ;
DUBOUCHER, C ;
IMBERT, C ;
KNIGHT, C ;
KROPF, L ;
WALLSTEN, H .
RADIOLOGY, 1987, 164 (03) :709-714
[8]  
RUUTU M, 1983, SCAND J UROL NEPHROL, V17, P1
[9]  
SACHSE H, 1974, Fortschritte der Medizin, V92, P12
[10]  
TORMALA P, IN PRESS CLIN MATERI