IRRADIATION DEVICES AND TESTING FACILITIES FOR SMALL SPECIMENS OF LOW-ACTIVATION STEELS

被引:9
作者
TARTAGLIA, GP
DEVRIES, MI
HORSTEN, MG
SCHMITT, R
机构
[1] ECN, 1755 ZG PETTEN, NETHERLANDS
[2] KFK, IMFII, D-76021 KARLSRUHE, GERMANY
关键词
D O I
10.1016/0022-3115(94)91108-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Special facilities have been developed for monitoring the irradiation behaviour of the fatigue and fracture properties throughout the development steps of low-activation steels. The paper presents information on the irradiation devices and testing facilities. The validity of the experimental techniques is demonstrated with the results of low-cycle fatigue tests and fracture mechanics tests on small-size specimens.
引用
收藏
页码:1655 / 1660
页数:6
相关论文
共 6 条
[1]  
AHLF J, 1993, EUR15151 EN
[2]  
DEVRIES MI, 1993, ASTM STP, V1175, P558
[3]  
DEVRIES MI, 1987, ASTM STP, V956, P162
[4]  
RIETH M, 1993, KFK5243
[5]  
SCHMITT R, KFK692 PRIM BER
[6]  
TARTAGLIA GP, 1991, 1991 REAKT TAG BONN, P14