Modified birdcage coils for targeted imaging

被引:17
作者
Gasson, J [1 ]
Summers, IR [1 ]
Fry, ME [1 ]
Vennart, W [1 ]
机构
[1] UNIV EXETER,DEPT PHYS,MED PHYS GRP,EXETER EX4 4QL,DEVON,ENGLAND
关键词
MRI; radiofrequency coil; birdcage coil; signal-to-noise; knuckle; MCP;
D O I
10.1016/0730-725X(95)02003-C
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The design of a radiofrequency coil of U-shaped geometry, specifically intended to image individual knuckle joints of the hand, has been investigated, The coil geometry is that of a ''split and opened'' birdcage coil, The optimum leg positions for such a U-shaped coil have been theoretically predicted using a novel technique that considers both the signal-to-noise ratio and the homogeneity of the field-of-view. Two particular coils of this type have been constructed, each optimum for a different size of image space and assuming a different source of image noise (sample-dominated or coil-dominated). The experimentally determined radiofrequency fields produced by the coils correspond well to theory, Either coil can be used to obtain good-quality, high-resolution (130 mu m x 130 mu m in-plane) images in vivo of the first, second, or fifth metacarpophalangeal joints of the hand, sites of particular interest in the study of arthritis.
引用
收藏
页码:1003 / 1012
页数:10
相关论文
共 9 条
[1]   A 64 MHZ 1/2-BIRDCAGE RESONATOR FOR CLINICAL IMAGING [J].
BALLON, D ;
GRAHAM, MC ;
MIODOWNIK, S ;
KOUTCHER, JA .
JOURNAL OF MAGNETIC RESONANCE, 1990, 90 (01) :131-140
[2]   FINGERS - 3-DIMENSIONAL MR-IMAGING AND ANGIOGRAPHY WITH A LOCAL GRADIENT COIL [J].
BLACKBAND, SJ ;
CHAKRABARTI, I ;
GIBBS, P ;
BUCKLEY, DL ;
HORSMAN, A .
RADIOLOGY, 1994, 190 (03) :895-899
[3]  
Chen C.N., 1989, BIOMEDICAL MAGNETIC
[4]   HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF THE INTERPHALANGEAL JOINTS OF THE HAND [J].
FRY, ME ;
JACOBY, RK ;
HUTTON, CW ;
ELLIS, RE ;
PITTARD, S ;
VENNART, W .
SKELETAL RADIOLOGY, 1991, 20 (04) :273-277
[5]   AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T [J].
HAYES, CE ;
EDELSTEIN, WA ;
SCHENCK, JF ;
MUELLER, OM ;
EASH, M .
JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) :622-628
[6]   SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT [J].
HOULT, DI ;
RICHARDS, RE .
JOURNAL OF MAGNETIC RESONANCE, 1976, 24 (01) :71-85
[7]   A TECHNIQUE FOR DOUBLE RESONANT OPERATION OF BIRDCAGE IMAGING COILS [J].
JOSEPH, PM ;
LU, DF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (03) :286-294
[8]  
TROOP J, 1989, J MAGN RESON, V82, P51
[9]   TRANSMISSION-LINE ANALYSIS OF NONCYLINDRICAL BIRDCAGE RESONATORS [J].
VULLO, T ;
PASCONE, R ;
MANCUSO, R ;
ZIPAGAN, R ;
CAHILL, PT .
MAGNETIC RESONANCE IMAGING, 1994, 12 (05) :785-797