AN INTERACTIVE GRAPHICS-BASED MODEL OF THE LOWER-EXTREMITY TO STUDY ORTHOPEDIC SURGICAL-PROCEDURES

被引:1507
作者
DELP, SL [1 ]
LOAN, JP [1 ]
HOY, MG [1 ]
ZAJAC, FE [1 ]
TOPP, EL [1 ]
ROSEN, JM [1 ]
机构
[1] STANFORD UNIV, DEPT MECH ENGN, DIV DESIGN, STANFORD, CA 94305 USA
基金
美国国家科学基金会;
关键词
D O I
10.1109/10.102791
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
We have developed a model of the human lower extremity to study how surgical changes in musculoskeletal geometry and musculotendon parameters affect muscle force and its moment about the joints. The lines of action of 43 musculotendon actuators were defined based on their anatomical relationships to three-dimensional bone surface representations. A model for each actuator was formulated to compute its isometric force-length relation. The kinematics of the lower extremity were defined by modeling the hip, knee, ankle, subtalar, and metatarsophalangeal joints. Thus, the force and joint moment that each musculotendon actuator develops can be computed for any body position. The joint moments calculated with the model compare well with experimentally measured isometric joint moments. We developed a graphical interface to the model that allows the user to visualize the musculoskeletal geometry and to manipulate the model parameters to study the biomechanical consequences of orthopaedic surgical procedures. For example, tendon transfer and lengthening procedures can be simulated by adjusting the model parameters according to various surgical techniques. Results of the simulated surgeries can be analyzed quickly in terms of postsurgery muscle forces and other biomechanical variables. Just as interactive graphics have enhanced engineering design and analysis, we have found that graphics-based musculoskeletal models are effective tools for designing and analyzing surgical procedures. © 1990 IEEE
引用
收藏
页码:757 / 767
页数:11
相关论文
共 46 条
[1]
BLECK EE, 1987, ORTHOPAEDIC MANAGEME, P213
[2]
Brand R A, 1984, Hip, P193
[3]
A MODEL OF LOWER-EXTREMITY MUSCULAR ANATOMY [J].
BRAND, RA ;
CROWNINSHIELD, RD ;
WITTSTOCK, CE ;
PEDERSEN, DR ;
CLARK, CR ;
VANKRIEKEN, FM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (04) :304-310
[4]
THE SENSITIVITY OF MUSCLE FORCE PREDICTIONS TO CHANGES IN PHYSIOLOGICAL CROSS-SECTIONAL AREA [J].
BRAND, RA ;
PEDERSEN, DR ;
FRIEDERICH, JA .
JOURNAL OF BIOMECHANICS, 1986, 19 (08) :589-596
[5]
A SYSTEM FOR 3-DIMENSIONAL INTERACTIVE SIMULATION OF HAND BIOMECHANICS [J].
BUFORD, WL ;
THOMPSON, DE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (06) :444-453
[6]
CAHALAN TD, 1989, CLIN ORTHOP RELAT R, P136
[7]
Delp S.L, 1990, THESIS STANFORD U ST
[8]
DELP SL, 1990, CLIN ORTHOP RELAT R, P189
[9]
Dul J, 1985, Eng Med, V14, P31, DOI 10.1243/EMED_JOUR_1985_014_006_02
[10]
EYCHLESHYMER AC, 1970, CROSS SECTION ANATOM