The response functions of the HEPC/LEPC detector system measured at the Xe L edge region

被引:16
作者
BudtzJorgensen, C [1 ]
Olesen, C [1 ]
Schnopper, HW [1 ]
Lederer, T [1 ]
Scholze, F [1 ]
Ulm, G [1 ]
机构
[1] PHYS TECH BUNDESANSTALT,D-10587 BERLIN,GERMANY
关键词
D O I
10.1016/0168-9002(95)00570-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Danish Space Research Institute will provide a set of two low energy proportional counters (LEPC) and two high energy proportional counters (HEPC) for the Russian SPECTRUM-X-Gamma mission. The detectors are based upon the technology of the microstrip gas chamber (MSGC). HEPC and LEPC use a Xe/CH4 mixture as the counter gas. The response function as well as the pulse height-energy relation for a Xe/CH4 filled MSGC were investigated with monochromatized synchrotron radiation of the BESSY double crystal monochromator. The detector response functions were recorded at similar to 100 selected photon energies in the range from 1.8 to 5.9 keV. The response functions were measured with photon energy steps of 5 eV around the Xe L subshells. The average pulse height versus photon energy relation shows clear jumps at the L edges of 55 eV, 25.6 eV and 153. eV at the L(3), L(2) and L(1) shell, respectively. The widths of the pulse height distributions indicate an increase of the Fano factor for Xe at the L absorption edges. These results are in good agreement with earlier predictions. Detailed analysis of the shape of the photopeaks as well as of the tail and escape contributions will also be presented.
引用
收藏
页码:83 / 87
页数:5
相关论文
共 11 条
[1]   FEATURES OF THE MICROSTRIP PROPORTIONAL COUNTER TECHNOLOGY [J].
BUDTZJORGENSEN, C .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :648-654
[2]  
BUDTZJORGENSEN C, 1988, SPIE P, V982, P152
[3]   THE FANO FACTOR IN GASEOUS XENON - A MONTE-CARLO CALCULATION FOR X-RAYS IN THE 0.1 TO 25 KEV ENERGY-RANGE [J].
DIAS, THVT ;
SANTOS, FP ;
STAUFFER, AD ;
CONDE, CAN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 307 (2-3) :341-346
[4]   THE ENERGY LINEARITY OF GASEOUS XENON RADIATION DETECTORS FOR X-RAYS WITH ENERGIES BETWEEN 2 AND 60-KEV - EXPERIMENTAL RESULTS [J].
DOSSANTOS, JMF ;
CONDE, CAN ;
BENTO, ACSSM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 324 (03) :611-613
[5]  
FELDHAUS J, 1980, SPIE P, V733, P242
[7]   THE IN-ORBIT PERFORMANCE OF THE EXOSAT GAS SCINTILLATION PROPORTIONAL COUNTER [J].
PEACOCK, A ;
TAYLOR, BG ;
WHITE, N ;
COURVOISIER, T ;
MANZO, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) :108-111
[8]   PHOTOMULTIPLIER SINGLE-ELECTRON STATISTICS AND THE SHAPE OF THE IDEAL SCINTILLATION LINE [J].
PRESCOTT, JR .
NUCLEAR INSTRUMENTS & METHODS, 1963, 22 (02) :256-268
[9]  
SANTOS FP, 1991, NUCL INSTRUM METH A, V307, P347
[10]  
SCHNOPPER HW, 1994, SPIE P, V2279, P64