COMPARISON BETWEEN A NEW COMPUTERIZED AND AN ANALOG VIDEOPHOTOMETRIC, CROSS-CORRELATION TECHNIQUE FOR MEASURING SKIN CAPILLARY BLOOD-CELL VELOCITY IN HUMANS

被引:20
作者
FAGRELL, B
ROSEN, L
ERIKSSON, SE
机构
[1] AKER HOSP,VASC RES LAB,N-0514 OSLO,NORWAY
[2] SWEDISH INST MICROELECTR,STOCKHOLM,SWEDEN
来源
INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL | 1994年 / 14卷 / 03期
关键词
BLOOD CELL VELOCITY; CROSS-CORRELATION TECHNIQUES; SKIN MICROCIRCULATION; VIDEOPHOTOMETRIC CAPILLAROSCOPY;
D O I
10.1159/000105065
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The capillary blood cell velocity (CBV) was measured using two different cross-correlation systems. Cross-correlation was performed by (1) a self-tracking, analogue cross-correlation technique and (2) by a new fully computerized system. The CBV was measured at rest and during venous occlusion and postocclusive reactive hyperemia (PRH) after 1-min arterial occlusion. The PRH response was described by determining the peak CBV. The correlations between the values obtained by the two systems were highly significant. CBV at rest: r = 0.97 (p < 0.001); CBV during venous occlusion: r = 0.97 (p < 0.001), peak CBV during PRH: r = 0.97 (p < 0.001). The stability of measurements with the computerized system was high. Only 0.08% of CBV variations was due to repeated measurements. This computerized system represents a reliable innovation which greatly facilitates CBV measurements, especially in clinical practice. The program includes automatic calculation of data (mean and maximum and minimum CBV, area under the curve, and integral, etc.).
引用
收藏
页码:133 / 138
页数:6
相关论文
共 12 条
[1]   RED BLOOD-CELL VELOCITY IN NAILFOLD CAPILLARIES OF MAN MEASURED BY A TELEVISION MICROSCOPY TECHNIQUE [J].
BOLLINGER, A ;
BUTTI, P ;
BARRAS, JP ;
TRACHSLER, H ;
SIEGENTHALER, W .
MICROVASCULAR RESEARCH, 1974, 7 (01) :61-72
[2]  
BOLLINGER A, 1976, ACTA CHIR SCAND, V465, P7
[3]  
BRANEMARK P.-I., 1963, BIORHEOLOGY, V1, P143
[4]   MICROSCOPE-TELEVISION SYSTEM FOR STUDYING FLOW VELOCITY IN HUMAN-SKIN CAPILLARIES [J].
FAGRELL, B ;
FRONEK, A ;
INTAGLIETTA, M .
AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 233 (02) :H318-H321
[5]   NAILFOLD VIDEOMICROSCOPY AND LOCAL COLD TEST IN TYPE-I DIABETICS [J].
GASSER, P ;
BERGER, W .
ANGIOLOGY, 1992, 43 (05) :395-400
[6]   CAPILLARY FLOW VELOCITY-MEASUREMENTS INVIVO AND INSITU BY TELEVISION METHODS [J].
INTAGLIETTA, M ;
SILVERMAN, NR ;
TOMPKINS, WR .
MICROVASCULAR RESEARCH, 1975, 10 (02) :165-179
[7]  
Montgomery D.C, 2011, DESIGN ANAL EXPT, V7th
[8]  
OSTEGREN J, 1984, SKIN CAPILLARY CIRCU
[9]  
PRIES AR, 1989, SPIE, V1357, P257
[10]  
SILVA J, 1974, MICROVASC RES, V1, P156