REAL-TIME BIPLANAR NEEDLE TRACKING FOR INTERVENTIONAL MR-IMAGING PROCEDURES

被引:67
作者
LEUNG, DA
DEBATIN, JF
WILDERMUTH, S
HESKE, N
DUMOULIN, CL
DARROW, RD
HAUSER, M
DAVIS, CP
VONSCHULTHESS, GK
机构
[1] UNIV ZURICH HOSP,DEPT RADIOL,CH-8091 ZURICH,SWITZERLAND
[2] BIOMED INSTUMENTE & PROD,MUNICH,GERMANY
[3] GE CO,CORP RES & DEV,SCHENECTADY,NY 12301
关键词
BIOPSIES; TECHNOLOGY; INTERVENTIONAL PROCEDURES; MAGNETIC RESONANCE (MR); GUIDANCE;
D O I
10.1148/radiology.197.2.7480698
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate real-time biplanar tracking of a specially designed needle with magnetic resonance (MR) imaging guidance. MATERIALS AND METHODS: The needle is made of polyetheretherketone and has a miniature radio-frequency coil incorporated into the tip. Tracking software on two workstations is used to compute three-dimensional coordinates of the coil and to display the position as a moving symbol in two imaging planes. Validation of needle tracking was performed in a harvested human liver. T2-weighted fast spin-echo images were used to target a 1-cm cyst. Success of needle placement was confirmed with aspiration and with updated gradient-recalled-echo images. RESULTS: The cyst was successfully targeted from different approaches. Tracking procedures were monitored in real time simultaneously on two separate images. CONCLUSION: Real-time biplanar needle tracking may prove to be useful for both diagnostic and therapeutic interventional MR imaging procedures.
引用
收藏
页码:485 / 488
页数:4
相关论文
共 18 条
[1]  
ALBERT K, 1994, BIO-MED MATER ENG, V4, P199
[2]   SIMULTANEOUS ACQUISITION OF PHASE-CONTRAST ANGIOGRAMS AND STATIONARY-TISSUE IMAGES WITH HADAMARD ENCODING OF FLOW-INDUCED PHASE-SHIFTS [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD ;
PELC, NJ ;
ADAMS, WJ ;
ASH, SA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (04) :399-404
[3]   REAL-TIME POSITION MONITORING OF INVASIVE DEVICES USING MAGNETIC-RESONANCE [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :411-415
[4]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[5]   SIMULTANEOUS TEMPORAL RESOLUTION OF CARDIAC AND RESPIRATORY MOTION IN MR-IMAGING [J].
FREDRICKSON, JO ;
WEGMULLER, H ;
HERFKENS, RJ ;
PELC, NJ .
RADIOLOGY, 1995, 195 (01) :169-175
[6]   PHASE-CONTRAST MR ANGIOGRAPHY WITH REDUCED ACQUISITION TIME - NEW CONCEPTS IN SEQUENCE DESIGN [J].
HAUSMANN, R ;
LEWIN, JS ;
LAUB, G .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (04) :415-422
[7]  
Jokish K. A., 1992, J BIOMED MATER RES, V26, P133
[8]  
JOLESZ FA, 1994, MAGN RESON QUART, V10, P85
[9]   INTRAVASCULAR MR TRACKING CATHETER - PRELIMINARY EXPERIMENTAL EVALUATION [J].
LEUNG, DA ;
DEBATIN, JF ;
WILDERMUTH, S ;
MCKINNON, GC ;
HOLTZ, D ;
DUMOULIN, CL ;
DARROW, RD ;
HOFMANN, E ;
VONSCHULTHESS, GK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1265-1270
[10]   NEW NEEDLE FOR MR-GUIDED ASPIRATION CYTOLOGY OF THE HEAD AND NECK [J].
LUFKIN, R ;
TERESI, L ;
HANAFEE, W .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (02) :380-382