OBSERVATIONS ON THE USE OF PELLET DIRECT SAMPLE INSERTION FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY

被引:12
作者
BLAIN, L [1 ]
SALIN, ED [1 ]
机构
[1] MCGILL UNIV,DEPT CHEM,801 SHERBROOKE ST W,MONTREAL H3A 2K6,QUEBEC,CANADA
关键词
D O I
10.1016/0584-8547(92)80034-E
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The feasibility of analyzing geological materials by the use of the direct sample insertion (DSI) technique into the inductively coupled plasma was assessed with a sediment reference material. PACS-1 (NRCC). Sharp and intense peaks were recorded for elements of high and intermediate volatility (As, Cd, Cu, Hg, Mn, Pb, Se, Sn, Zn) after the insertion of pellets prepared from 1:5 mixtures of PACS-1 in graphite. Probe geometry and plasma RF power were optimized to enhance both the magnitude of the signals and the temporal resolution of spectral overlaps. A variable integration time base was found essential to allow good observation of the signals of analytes ranging from volatile trace level elements to refractory matrix constituents. The use of thermochemical additives to enhance the vaporization of refractory elements was investigated. It was found that chloride releasing reagents were preferable to fluoride salts, because the fluorides caused a sudden massive release of Si into the plasma, which resulted in severe physical and spectral interferences.
引用
收藏
页码:399 / 423
页数:25
相关论文
共 34 条
[1]   SIMULTANEOUS MULTIELEMENT ANALYSIS OF MICROLITER VOLUMES OF SOLUTION SAMPLES BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY UTILIZING A GRAPHITE CUP DIRECT INSERTION TECHNIQUE [J].
ABDULLAH, M ;
FUWA, K ;
HARAGUCHI, H .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (9-11) :1129-1139
[2]  
AHRENS LH, 1961, SPECTROCHEMICAL ANAL
[3]  
AVNI R, 1972, APPL SPECTROSC, V26, P641
[4]   DESIGN CONSIDERATION AND TEMPERATURE DETERMINATION OF AN AUTOMATED GRAPHITE-FURNACE CUP SYSTEM USED FOR DIRECT SAMPLE INTRODUCTION FOR ICP OPTICAL-EMISSION SPECTROMETRY [J].
BARNETT, NW ;
COPE, MJ ;
KIRKBRIGHT, GF ;
TAOBI, AAH .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (2-3) :343-348
[5]   PROBE DESIGN FOR THE DIRECT INSERTION OF SOLID SAMPLES IN THE INDUCTIVELY COUPLED PLASMA FOR ANALYSIS BY ATOMIC EMISSION AND MASS-SPECTROMETRY [J].
BLAIN, L ;
SALIN, ED ;
BOOMER, DW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (08) :721-725
[6]   METHODOLOGICAL SOLUTIONS FOR THE ANALYSIS OF SEDIMENT SAMPLES BY DIRECT SAMPLE INSERTION INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION [J].
BLAIN, L ;
SALIN, ED .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (02) :205-217
[7]  
BLAIN L, 1991, THESIS MCGILL U
[8]   TRACE-ELEMENT ANALYSIS OF GEOLOGICAL-MATERIALS BY DIRECT SOLIDS INSERTION OF A GRAPHITE CUP INTO AN INDUCTIVELY COUPLED PLASMA [J].
BRENNER, IB ;
LORBER, A ;
GOLDBART, Z .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) :219-225
[9]  
BURGENER P, 1988, ICP INFORM NEWSL, V13, P521
[10]  
BURMAN JO, 1987, CHEM ANAL SERIES, V90