A NEW DEVICE FOR EXPOSING THE CIRCUMFLEX CORONARY-ARTERY

被引:6
作者
MATSUURA, A
YASUURA, K
MASEKI, T
ICHIHARA, T
MIYAHARA, K
ITOH, T
WATANABE, T
MURASE, M
机构
[1] Department of Thoracic Surgery, Nagoya University School of Medicine, Nagoya
关键词
D O I
10.1016/0003-4975(95)00093-Z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We have devised a new retractor for use in coronary artery bypass grafting that is made from three woven Teflon tapes. This method allows sufficient counterclockwise rotation of the heart, provides excellent exposure of the posterior and inferior coronary artery systems, and creates a horizontal surgical plane for the circumflex anastomosis.
引用
收藏
页码:1249 / 1250
页数:2
相关论文
共 4 条
[2]   CIRCUMFLEX EXPOSURE USING A CARDIAC SLING [J].
GALVIN, IF ;
NEWMAN, DC .
ANNALS OF THORACIC SURGERY, 1990, 49 (05) :833-834
[3]  
JANKE WH, 1974, J THORAC CARDIOV SUR, V67, P883
[4]   FABRIC HEART RETRACTOR FOR CORONARY-ARTERY BYPASS OPERATIONS [J].
KAZAMA, S ;
ISHIHARA, A .
ANNALS OF THORACIC SURGERY, 1993, 55 (06) :1582-1583