PROJECTION PRESATURATION .3. ACCURATE SELECTIVE EXCITATION OR PRESATURATION OF THE REGIONS OF TAILORED SHAPE IN THE PRESENCE OF SHORT-T(1) SPECIES

被引:10
作者
SINGH, S [1 ]
BRODY, WR [1 ]
机构
[1] JOHNS HOPKINS UNIV,SCH MED,DEPT RADIOL,DIV MAGNET RESONANCE RES,600 N WOLFE ST,BALTIMORE,MD 21205
来源
JOURNAL OF MAGNETIC RESONANCE SERIES B | 1993年 / 101卷 / 01期
关键词
D O I
10.1006/jmrb.1993.1007
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A new method is described which further increases the accuracy of localization by projection presaturation (PP), a technique for multidimensional spatial localization of contoured regions of interest (ROIs), whose shape, size, position, and number can be chosen arbitrarily (J. Magn. Reson.90, 313, 1990). By applying a nonselective radiofrequency inversion pulse after the PP saturation cycle and nulling the residual longitudinal magnetization of the region outside the ROI, the outer-volume signal is suppressed to the "noise" level, thus improving the accuracy of the basic PP localization, even when saturating a large exterior volume of short-T1 species. The ability of the method to perform spatial and spectral localization simultaneously is also described. Alternatively, the single-shot methods for selective saturation (instead of selective excitation) of single or multiple contoured regions at arbitrary positions in an extended volume are presented. In particular, the results of selective excitation and saturation of a region of conformal geometric shape in two and three dimensions in a phantom as well as in vivo (healthy volunteers) are presented to demonstrate the efficacy of the method. Applications of these methods include flow- and motion-artifact suppression in body MRI, accurate conformal localization for in vivo spectroscopy in the presence of chemical shift, outer-volume suppression for resolution or speed enhancement in ultrafast imaging (Magn. Reson. Med.13, 77, 1990; J. Phys. C10, L55, 1977), and spin tagging by selective excitation/saturation of flowing spins for flow studies and angiography. © 1993 Academic Press, Inc.
引用
收藏
页码:52 / 62
页数:11
相关论文
共 14 条
[1]   POWER DEPOSITION IN WHOLE-BODY NMR IMAGING [J].
BOTTOMLEY, PA ;
EDELSTEIN, WA .
MEDICAL PHYSICS, 1981, 8 (04) :510-512
[2]   NMR CHEMICAL-SHIFT IMAGING IN 3 DIMENSIONS [J].
BROWN, TR ;
KINCAID, BM ;
UGURBIL, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (11) :3523-3526
[3]   THRESHOLDS FOR PHYSIOLOGICAL-EFFECTS DUE TO RF AND MAGNETIC-FIELDS USED IN NMR IMAGING [J].
BUDINGER, TF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2821-2825
[4]   SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING [J].
FELMLEE, JP ;
EHMAN, RL .
RADIOLOGY, 1987, 164 (02) :559-564
[5]   SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89
[7]   MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES [J].
MANSFIELD, P .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03) :L55-L58
[8]   A NEW SELECTIVE PRESATURATION PULSE FOR IMAGING AND SPECTROSCOPY [J].
MAO, JT ;
YAN, H .
JOURNAL OF MAGNETIC RESONANCE, 1991, 92 (02) :421-428
[9]  
SHUNGU D, 1992, 11TH SOC MAGN RES ME, V2, P3520
[10]   PROJECTION PRESATURATION .2. SINGLE-SHOT LOCALIZATION OF MULTIPLE REGIONS OF INTEREST [J].
SINGH, S ;
RUTT, BK ;
NAPEL, S .
JOURNAL OF MAGNETIC RESONANCE, 1990, 90 (02) :313-329