A radio-frequency glow discharge induced graft copolymerization process has prepared a PAAc-grafted PE film in this present study. Poly (ethylene oxide) (PEO) was then covalently immobilized onto PAAc-grafted PE film by a chemical coupling reaction. Carboxylic groups were introduced onto the surface of PE film by exposing the film to an Ar plasma, and the plasma-treated film was then next reacted with a 50% acrylic acid aqueous solution. These functional groups were reacted with bisamino PEO by a coupling agent CMC. ESCA, IR, and water contact angle studies were conducted for characterizing the surfaces of these films during the varied stages of the reaction. Increasing the molecular weight of the PEO attached to the PAAc-grafted PE resulted in an increased wettability of the films. (C) 1993 John Wiley & Sons, Inc.
引用
收藏
页码:2601 / 2607
页数:7
相关论文
共 25 条
[1]   PLATELET DEPOSITION STUDIES ON COPOLYETHER URETHANES MODIFIED WITH POLY (ETHYLENE-OXIDE) [J].
BRINKMAN, E ;
POOT, A ;
VANDERDOES, L ;
BANTJES, A .
BIOMATERIALS, 1990, 11 (03) :200-205
[2]  
CLARK DT, 1977, ADV POLYM SCI, V24, P125
[3]  
DACOSTA VS, 1981, J COLLOID INTERF SCI, V80, P445
[4]   BIOLOGICAL RESPONSES TO POLYETHYLENE OXIDE MODIFIED POLYETHYLENE TEREPHTHALATE SURFACES [J].
DESAI, NP ;
HUBBELL, JA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07) :829-843
[5]  
Golander C.G., 1987, PROGR COLLOID POLYM, V74, P113, DOI [10.1007/BF01191021, DOI 10.1007/BF01191021]
[6]   IMMOBILIZATION OF POLY(ETHYLENE OXIDE) ON POLY(ETHYLENE-TEREPHTHALATE) USING A PLASMA POLYMERIZATION PROCESS [J].
GOMBOTZ, WR ;
GUANGHUI, W ;
HOFFMAN, AS .
JOURNAL OF APPLIED POLYMER SCIENCE, 1989, 37 (01) :91-107
[7]   PROTEIN ADSORPTION TO POLY(ETHYLENE OXIDE) SURFACES [J].
GOMBOTZ, WR ;
GUANGHUI, W ;
HORBETT, TA ;
HOFFMAN, AS .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (12) :1547-1562
[8]   PROTEIN ADSORPTION FROM BUFFER AND PLASMA ONTO HYDROPHILIC HYDROPHOBIC POLY(ETHYLENE OXIDE) POLYSTYRENE MULTIBLOCK COPOLYMERS [J].
GRAINGER, DW ;
OKANO, T ;
KIM, SW .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1989, 132 (01) :161-175
[9]   SURFACE-PROPERTIES AND BLOOD COMPATIBILITY OF POLYURETHANEUREAS [J].
GRASEL, TG ;
COOPER, SL .
BIOMATERIALS, 1986, 7 (05) :315-328
[10]   THE CATION-CHELATION MECHANISM OF METAL-ION SORPTION BY POLYURETHANES [J].
HAMON, RF ;
KHAN, AS ;
CHOW, A .
TALANTA, 1982, 29 (04) :313-326