ANALYSIS OF PULSED WAVE DOPPLER ULTRASOUND SPECTRA OBTAINED FROM A MODEL INTRACORONARY CATHETER

被引:6
作者
DENARDO, SJ
TALBOT, L
HARGRAVE, VK
FITZGERALD, PJ
SELFRIDGE, AR
YOCK, PG
机构
[1] UNIV CALIF SAN FRANCISCO,CARDIOVASC RES INST,SAN FRANCISCO,CA 94143
[2] UNIV CALIF BERKELEY,DEPT MECH ENGN,BERKELEY,CA 94720
[3] ULTRASON DEVICES INC,LOS GATOS,CA 95030
关键词
D O I
10.1109/10.301730
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Abnormal arterial blood flow patterns have been implicated in the evolution of various vascular disease processes. Intravascular ultrasound techniques using the pulsed wave Doppler catheter offer the opportunity to characterize these abnormal flow patterns. We have developed a mathematical model that predicts the first two moments of the Doppler spectrum obtained using a Doppler catheter based on the distribution of ultrasonic beam power and velocity profile of fluid flow with an arbitrary distribution of flow disturbances. A scaled-up, invitro experimental arterial system was used to confirm the validity of the model. Comparison of the predicted first two moments of the Doppler spectrum to the experimental values in this system demonstrated that the distribution of beam power significantly affects the magnitude of the first two moments. Additionally, both velocity gradient and velocity fluctuation broadening effects play prominent roles in determining the magnitude of the second moment. These phenomena must therefore be considered when evaluating invivo Doppler spectra used for the characterization of abnormal flow patterns.
引用
收藏
页码:635 / 648
页数:14
相关论文
共 25 条
[1]  
Adrian R. J., 1983, Fluid mechanics measurements, P155
[2]   FLOW PATTERNS AND SPATIAL-DISTRIBUTION OF ATHEROSCLEROTIC LESIONS IN HUMAN CORONARY-ARTERIES [J].
ASAKURA, T ;
KARINO, T .
CIRCULATION RESEARCH, 1990, 66 (04) :1045-1066
[3]   INFLUENCE OF BEAM PROFILE AND DEGREE OF INSONATION ON THE CW DOPPLER ULTRASOUND SPECTRUM AND MEAN VELOCITY [J].
COBBOLD, RSC ;
VELTINK, PH ;
JOHNSTON, KW .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1983, 30 (06) :364-370
[4]   PULSED DOPPLER CORONARY-ARTERY CATHETER - PRELIMINARY-REPORT OF A NEW TECHNIQUE FOR MEASURING RAPID CHANGES IN CORONARY-ARTERY FLOW VELOCITY IN MAN [J].
COLE, JS ;
HARTLEY, CJ .
CIRCULATION, 1977, 56 (01) :18-25
[5]  
DAVIES PF, 1986, P NATL ACAD SCI USA, V83, P2114, DOI 10.1073/pnas.83.7.2114
[6]  
DENARDO SJ, 1989, CIRC S2, V80, P371
[7]  
EVANS DH, 1989, DOPPLER ULTRASOUND P, P171
[8]   MEASUREMENT OF FLUID TURBULENCE BASED ON PULSED ULTRASOUND TECHNIQUES .2. EXPERIMENTAL INVESTIGATION [J].
GARBINI, JL ;
FORSTER, FK ;
JORGENSEN, JE .
JOURNAL OF FLUID MECHANICS, 1982, 118 (MAY) :471-505
[9]   MEASUREMENT OF FLUID TURBULENCE BASED ON PULSED ULTRASOUND TECHNIQUES .1. ANALYSIS [J].
GARBINI, JL ;
FORSTER, FK ;
JORGENSEN, JE .
JOURNAL OF FLUID MECHANICS, 1982, 118 (MAY) :445-470
[10]  
HODGMAN CD, 1947, HDB CHEM PHYSICS, P1742