THE ION-CHROMATOGRAPHIC BEHAVIOR OF ARSENITE, ARSENATE, METHYLARSONIC ACID AND DIMETHYLARSINIC ACID ON THE HAMILTON PRP-X100 ANION-EXCHANGE COLUMN

被引:48
作者
GAILER, J [1 ]
IRGOLIC, KJ [1 ]
机构
[1] KARL FRANZENS UNIV GRAZ,INST ANALYT CHEM,UNIV PL 1,A-8010 GRAZ,AUSTRIA
关键词
ARSENITE; ARSENATE; METHYLARSONIC ACID; DIMETHYLARSINIC ACID; ANION-EXCHANGE CHROMATOGRAPHY; ARSENIC-SPECIFIC DETECTORS; FLAME ATOMIC ABSORPTION SPECTROMETRY; GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY;
D O I
10.1002/aoc.590080208
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The HPLC separation of arsenite, arsenate, methylarsonic acid and dimethylarsinic acid has been studied in the past but not in a systematic manner. The dependence of the retention times of these arsenic compounds on the PH of the mobile phase, on the concentration and the chemical composition of buffer solutions (phosphate, acetate, potassium hydrogen phthalate) and on the presence of sodium sulfate or nickel sulfate in the mobile phase was investigated using a Hamilton PRP-X100 anion-exchange column. With a flame atomic absorption detector and arsenic concentrations of at least 10 mg dm-3 all investigated mobile phases will separate the four arsenic compounds at appropriate pH values in the range 4-8. The shortest analysis time (approximately 3 min) was achieved with a 0.006 mol dm-3 potassium hydrogen phthalate mobile phase at pH 4, the longest (approximately 10 min) with 0.006 mol dm-3 sodium sulfate at pH 5.9 at a flow rate of 1.5 cm3 min-1. With a graphite furnace atomic absorption detector at the required, much lower, flow rate of approximately 0.2 cm3 min-1 acceptable separations were achievable only with the pH 6 phosphate buffer (0.03 mol dm-3) and the nickel sulfate solution (0.005 mol dm-3) as the mobile phase. To become detectable approximately 100 ng arsenic from each arsenic compound (100 mul injection) must be chromatographed with the phosphate buffer, and approximately 10 ng with the nickel sulfate solution.
引用
收藏
页码:129 / 140
页数:12
相关论文
共 14 条
[1]   APPLICATION OF A LIQUID CHROMATOGRAPH COUPLED WITH A FLAMELESS ATOMIC-ABSORPTION DETECTOR FOR SPECIATION OF TRACE ORGANOMETALLIC COMPOUNDS [J].
BRINCKMAN, FE ;
BLAIR, WR ;
JEWETT, KL ;
IVERSON, WP .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1977, 15 (11) :493-503
[2]   GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROPHOTOMETERS AS AUTOMATED ELEMENT-SPECIFIC DETECTORS FOR HIGH-PRESSURE LIQUID-CHROMATOGRAPHY - THE DETERMINATION OF ARSENITE, ARSENATE, METHYLARSONIC ACID AND DIMETHYLARSINIC ACID [J].
BRINCKMAN, FE ;
JEWETT, KL ;
IVERSON, WP ;
IRGOLIC, KJ ;
EHRHARDT, KC ;
STOCKTON, RA .
JOURNAL OF CHROMATOGRAPHY, 1980, 191 (APR) :31-46
[3]   MATRIX INTERFERENCES IN ARSENIC DETERMINATIONS BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY - RECOMMENDATIONS FOR THE DETERMINATION OF ARSENIC IN WATER SAMPLES [J].
CHAKRABORTI, D ;
IRGOLIC, KJ ;
ADAMS, F .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1984, 17 (3-4) :241-256
[4]   URINARY ARSENIC SPECIATION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ATOMIC-ABSORPTION SPECTROMETRY FOR MONITORING OCCUPATIONAL EXPOSURE TO INORGANIC ARSENIC [J].
CHANA, BS ;
SMITH, NJ .
ANALYTICA CHIMICA ACTA, 1987, 197 :177-186
[5]   ARSENIC SPECIATION IN THE ENVIRONMENT [J].
CULLEN, WR ;
REIMER, KJ .
CHEMICAL REVIEWS, 1989, 89 (04) :713-764
[6]   QUANTITATIVE-DETERMINATION OF ARSENOBETAINE, THE MAJOR WATER-SOLUBLE ARSENICAL IN 3 SPECIES OF CRAB, USING HIGH-PRESSURE LIQUID-CHROMATOGRAPHY AND AN INDUCTIVELY COUPLED ARGON PLASMA EMISSION SPECTROMETER AS THE ARSENIC-SPECIFIC DETECTOR [J].
FRANCESCONI, KA ;
MICKS, P ;
STOCKTON, RA ;
IRGOLIC, KJ .
CHEMOSPHERE, 1985, 14 (10) :1443-1453
[8]  
IRGOLIC KJ, 1991, TRACE METAL ANAL SPE, V47, P21
[9]  
IRGOLIC KJ, 1992, HAZARDOUS METALS ENV, P287
[10]   COMPUTERIZED DATA TREATMENT FOR AN HPLC-GFAAS SYSTEM FOR THE IDENTIFICATION AND QUANTIFICATION OF TRACE-ELEMENT COMPOUNDS [J].
KOLBL, G ;
KALCHER, K ;
IRGOLIC, KJ .
JOURNAL OF AUTOMATIC CHEMISTRY, 1993, 15 (02) :37-45