STUDIES ON THE APPLICATION OF PLATFORM ATOMIZATION TO FURNACE ATOMIC NONTHERMAL EXCITATION SPECTROMETRY FOR THE SIMULTANEOUS MULTIELEMENT ANALYSIS OF ENVIRONMENTAL MATERIALS

被引:8
作者
BAXTER, DC [1 ]
NICHOL, R [1 ]
LITTLEJOHN, D [1 ]
LUDKE, C [1 ]
SKOLE, J [1 ]
HOFFMANN, E [1 ]
机构
[1] INST SPEKTROCHEM & ANGEW SPEKTROSKOPIE,SPEKTROSKOP METHODEN UMWELTANALYT LAB,W-1199 BERLIN,GERMANY
关键词
FURNACE ATOMIC NONTHERMAL EXCITATION SPECTROMETRY; PLATFORM ATOMIZATION; MULTIELEMENT ANALYSIS; INTERFERENCE; ENVIRONMENTAL SAMPLE;
D O I
10.1039/ja9920700727
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Response surface methodology was used to optimize the discharge current and pressure with respect to detection limits for the simultaneous multi-element determination of Al, Cd, Cr, Cu, Fe, Ni and Pb by furnace atomic non-thermal excitation spectrometry (FANES). Comparison of wall and platform atomization showed improved detection limits for most elements with the latter. Despite the use of automatic background correction by wavelength modulation, residual background signals were observed at all lines, those on the Cd, Cu, Fe and Pb channels being rectified by including an 'autozero' procedure in the data processing software. For the remaining elements, spectral interferences disrupted the baseline during the atomization step, although blank subtraction provided satisfactory correction. Nevertheless, the presence of structured background emission poses a potentially serious source of error in FANES measurements. In the multi-element analysis of microwave-assisted digests of three environmental reference materials [National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 1572 Citrus Leaves, SRM 1575 Pine Needles and SRM 1645 River Sediment] by platform-equipped FANES, non-spectral interferences arose for all analytes except Cd and Pb. The use of the standard additions method was thus necessary for calibration purposes.
引用
收藏
页码:727 / 734
页数:8
相关论文
共 35 条
[1]   HOLLOW-ANODE PLASMA EXCITATION SOURCE FOR ATOMIC EMISSION-SPECTROMETRY [J].
BALLOU, NE ;
STYRIS, DL ;
HARNLY, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (08) :1141-1143
[2]  
BOX GEP, 1978, STATISTICS EXPT
[3]   SIMULTANEOUS MULTI-ELEMENT ANALYSIS BY CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY WITH GRAPHITE PROBE ELECTROTHERMAL ATOMIZATION [J].
CARROLL, J ;
MILLERIHLI, NJ ;
HARNLY, JM ;
LITTLEJOHN, D ;
OTTAWAY, JM ;
OHAVER, TC .
ANALYST, 1985, 110 (09) :1153-1159
[4]   ATOMIC SPECTROMETRY UPDATE - ENVIRONMENTAL-ANALYSIS [J].
CRESSER, MS ;
ARMSTRONG, J ;
DEAN, J ;
RAMSEY, MH ;
CAVE, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (01) :R1-R67
[5]   STUDIES ON THE DIRECT ANALYSIS OF SOLID PLANT MATERIALS USING FANES (FURNACE ATOMIC NONTHERMAL EXCITATION SPECTROMETRY) [J].
FALK, H ;
HOFFMANN, E ;
LUDKE, C ;
SCHMIDT, KP .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (08) :853-857
[6]   FURNACE ATOMIZATION WITH NON-THERMAL EXCITATION - EXPERIMENTAL EVALUATION OF DETECTION BASED ON A HIGH-RESOLUTION ECHELLE MONOCHROMATOR INCORPORATING AUTOMATIC BACKGROUND CORRECTION [J].
FALK, H ;
HOFFMANN, E ;
LUDKE, C ;
OTTAWAY, JM ;
GIRI, SK .
ANALYST, 1983, 108 (1293) :1459-1465
[7]   STUDIES ON THE DETERMINATION OF CADMIUM IN BLOOD BY FURNACE ATOMIC NONTHERMAL EXCITATION SPECTROMETRY [J].
FALK, H ;
HOFFMANN, E ;
LUDKE, C ;
OTTAWAY, JM ;
LITTLEJOHN, D .
ANALYST, 1986, 111 (03) :285-290
[8]  
FALK H, 1988, PROG ANAL SPECTROSC, V11, P417
[9]   FANES (FURNACE ATOMIC NONTHERMAL EXCITATION SPECTROMETRY) - A NEW EMISSION TECHNIQUE WITH HIGH DETECTION POWER [J].
FALK, H ;
HOFFMANN, E ;
LUDKE, C .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (08) :767-771
[10]  
FALK H, 1984, SPECTROCHIM ACTA B, V539, P283