IMAGE REGISTRATION FOR SUBTRACTION ANGIOGRAPHY IN SPIRAL CT

被引:3
作者
BEIER, J [1 ]
RICHTER, CS [1 ]
FLECK, E [1 ]
FELIX, R [1 ]
机构
[1] FREE UNIV BERLIN,KLINIKUM RUDOLF VIRCHOW,STRAHLEN & POLIKLIN,W-1000 BERLIN,GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1995年 / 162卷 / 01期
关键词
IMAGE REGISTRATION; IMAGE SUBTRACTION; DSA; SPIRAL CT; IMAGE PROCESSING;
D O I
10.1055/s-2007-1015835
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conventional image subtraction of CT sequences is hampered by extended motion artifacts. In this paper a motion correction procedure for the subtraction of images from two time-separate CT investigations is introduced. Native images are obtained in the first CT sequence, and a contrast medium examination is imaged in the second. The aim of image subtraction is sole presentation of the contrast medium. In contrast to conventional digital subtraction angiography (DSA), CT angiography rules out the possibility of direct image subtraction due to occurrence of extended motion artifacts in the time-shifted images. Such shortcomings can now be corrected by means of a new registration method developed for determination of local displacement vectors between the two images. This motion pattern is used to compute a new synthetic mask of maximum congruence with the contrast medium image. The resulting three-dimensional data record is presented by means of a special-purpose hardware enabling fast rotations and cut planes. New diagnostic possibilities can be achieved such as the creation of views that are not obtainable with conventional modalities and the assessment of calcified vessels.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 17 条
[1]  
COLLIGNON A, 1993, SPIE MED IMAGING, V1898, P14
[2]  
FABER TL, 1986, IEEE COMPUT VISION P, P440
[3]   RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY [J].
GALANSKI, M ;
PROKOP, M ;
CHAVAN, A ;
SCHAEFER, CM ;
JANDELEIT, K ;
NISCHELSKY, JE .
RADIOLOGY, 1993, 189 (01) :185-192
[4]  
GUITERREZ MA, 1993, COMPUT CARDIOL, V93, P37
[5]  
HABERACKER P, 1985, DIGITALE BILDVERARBE, P169
[6]  
Kalender W A, 1990, Rontgenpraxis, V43, P323
[7]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[8]  
LAMBERTI C, 1993, COMPUT CARDIOL, V93, P739
[9]   CT ANGIOGRAPHY WITH SPIRAL CT AND MAXIMUM INTENSITY PROJECTION [J].
NAPEL, S ;
MARKS, MP ;
RUBIN, GD ;
DAKE, MD ;
MCDONNELL, CH ;
SONG, SM ;
ENZMANN, DR ;
JEFFREY, RB .
RADIOLOGY, 1992, 185 (02) :607-610
[10]  
OLDENDORF M, 1993, ELECTRO MED, V1, P13