EARLY LOOSENING OF THE FEMORAL COMPONENT AT THE CEMENT-PROSTHESIS INTERFACE AFTER TOTAL HIP-REPLACEMENT

被引:132
作者
MOHLER, CG
CALLAGHAN, EJJ
COLLIS, DK
OREGON, E
JOHNSTON, RC
机构
[1] ORTHOPAED & FRACTURE CLIN EUGENE, EUGENE, OR 97401 USA
[2] UNIV IOWA, COLL MED, IOWA CITY, IA USA
关键词
D O I
10.2106/00004623-199509000-00004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Between 1980 and 1990, 1941 total hip replacements were performed with use of the Iowa femoral component fixed,vith cement. Twenty-seven of these patients (twenty-nine hips) had early loosening of the femoral component two to ten years (average, five years) after the operation. The average age of these patients at the time of the operation was fifty-nine years (range, forty-one to seventy-seven years). The acetabular cup had been inserted without cement in seventeen hips, and the cup had been inserted with cement in twelve. The femoral stems had a matte finish; twenty had been precoated with polymethylmethacrylate and nine had not been precoated. The pattern of loosening of the femoral stem was unique: in each hip, the loosening was initially reflected by debonding (a superolateral lucency between the cement and the prosthesis in zone 1 of Gruen et al.), and this was followed by progressive loosening at the cement-prosthesis interface with maintenance of the bone-cement interface. In twenty hips, the debonding was followed by extensive osteolysis. Twenty patients (twenty-one hips) had a revision, and one was considering a revision at the time of writing. The average time from the onset of the symptoms to the revision for the nineteen hips for which this information was available was nine months. We believe that both the geometry (a cylindrical shape distal to the proximal cobra shape) and the surface finish of the Iowa femoral component were responsible for the pattern of progressive loosening. We suggest that once debonding develops, the cylindrical shape of this particular stem allows rotation, permitting the roughened surface finish to abrade the polymethylmethacrylate, which results in loosening and osteolysis.
引用
收藏
页码:1315 / 1322
页数:8
相关论文
共 35 条
[1]  
AHMED A M, 1984, Journal of Orthopaedic Research, V2, P105, DOI 10.1002/jor.1100020201
[2]  
AMSTUTZ HC, 1976, HIP, P102
[3]   THE EFFECT OF SURFACE PREPARATION ON METAL BONE-CEMENT INTERFACIAL STRENGTH [J].
BUNDY, KJ ;
PENN, RW .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (06) :773-805
[4]   CENTRIFUGATION AS A METHOD OF IMPROVING TENSILE AND FATIGUE PROPERTIES OF ACRYLIC BONE-CEMENT [J].
BURKE, DW ;
GATES, EI ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (08) :1265-1273
[5]  
CALLAGHAN JJ, 1992, CLIN ORTHOP RELAT R, V276, P33
[6]  
COLLIS DK, 1988, ORTHOP CLIN N AM, V19, P541
[7]   LONG-TERM (12 TO 18-YEAR) FOLLOW-UP OF CEMENTED TOTAL HIP REPLACEMENTS IN PATIENTS WHO WERE LESS THAN 50 YEARS OLD - A FOLLOW-UP NOTE [J].
COLLIS, DK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (04) :593-597
[8]   ANALYSIS OF FEMORAL COMPONENT STEM DESIGN IN TOTAL HIP-ARTHROPLASTY [J].
CROWNINSHIELD, RD ;
BRAND, RA ;
JOHNSTON, RC ;
MILROY, JC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (01) :68-78
[9]   CEMENT STRAIN-MEASUREMENT SURROUNDING LOOSE AND WELL-FIXED FEMORAL COMPONENT STEMS [J].
CROWNINSHIELD, RD ;
TOLBERT, JR .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (05) :819-828
[10]   FRACTURE AND LOOSENING OF CHARNLEY FEMORAL STEMS - COMPARISON BETWEEN 1ST-GENERATION AND SUBSEQUENT DESIGNS [J].
DALL, DM ;
LEARMONTH, ID ;
SOLOMON, MI ;
MILES, AW ;
DAVENPORT, JM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :259-265