SELECTIVE ION ISOLATION REJECTION OVER A BROAD MASS RANGE IN THE QUADRUPOLE ION TRAP

被引:122
作者
MCLUCKEY, SA
GOERINGER, DE
GLISH, GL
机构
[1] Analytical Chemistry Division, Oak Ridge National Laboratory, Oak Ridge, 37831-6365, TN
关键词
D O I
10.1016/1044-0305(91)80056-D
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Techniques are presented for mass-selective ion manipulation over a wide mass range in a three-dimensional quadrupole. The methods use an auxiliary, low-amplitude radio-frequency signal applied to the endcap electrodes. The signal is either held at a single frequency as the fundamental radio-frequency trapping amplitude is ramped or swept over a frequency range while the fundamental radio-frequency trapping amplitude is held at a fixed level. Ion isolation and ejection are demonstrated for ions formed within the ion trap using electron ionization and for ions injected into the ion trap formed either by an air-sustained glow discharge or by electrospray. Mass-selective ion ejection is used to reduce matrix-ion-induced space charge during ion injection, thereby producing signal enhancement for the detection of 2,4,6-trinitrotoluene in air. Mass-selective isolation of ions with mass-to-charge ratios above the normal operating range (m/z 650) for the ion trap is also demonstrated after injection of myoglobin ions formed via electrospray.
引用
收藏
页码:11 / 21
页数:11
相关论文
共 27 条
[1]  
DAWSON PH, 1969, AFCRL690185
[2]   DIE DREIDIMENSIONALE STABILISIERUNG VON LADUNGSTRAGERN IN EINEM VIERPOLFELD [J].
FISCHER, E .
ZEITSCHRIFT FUR PHYSIK, 1959, 156 (01) :1-26
[3]   NEW MODE OF OPERATION FOR 3-DIMENSIONAL QUADRUPOLE ION STORE (QUISTOR) - SELECTIVE ION REACTOR [J].
FULFORD, JE ;
MARCH, RE .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1978, 26 (02) :155-162
[4]   RADIO-FREQUENCY MASS SELECTIVE EXCITATION AND RESONANT EJECTION OF IONS IN A 3-DIMENSIONAL QUADRUPOLE ION TRAP [J].
FULFORD, JE ;
HOA, DN ;
HUGHES, RJ ;
MARCH, RE ;
BONNER, RF ;
WONG, GJ .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1980, 17 (04) :829-835
[5]  
Hemberger P. H., 1989, RAPID COMMUN MASS SP, V3, P50
[6]  
KELLEY PE, 1985, Patent No. 4540884
[7]  
KELLEY PE, 1986, 34TH P C MASS SPECTR, P963
[8]  
KELLEY PE, 1984, 32ND P ASMS C MASS S, P505
[9]  
Louris J. N., 1989, RAPID COMMUN MASS SP, V3, P225
[10]   INJECTION OF IONS INTO A QUADRUPOLE ION TRAP MASS-SPECTROMETER [J].
LOURIS, JN ;
AMY, JW ;
RIDLEY, TY ;
COOKS, RG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 88 (2-3) :97-111