A METHOD OF RATE-CONSTANT MEASUREMENT IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE PULSED VALVE EXPERIMENTS

被引:8
作者
LIN, Y
NICOL, GR
RIDGE, DP
机构
来源
EUROPEAN MASS SPECTROMETRY | 1995年 / 1卷 / 02期
关键词
RATE CONSTANT MEASUREMENTS; FT-ICR; PULSED-VALVE; RE-2(+); CYCLOHEXANE;
D O I
10.1255/ejms.144
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Rate constant measurements in Fourier-transform ion cyclotron resonance (PT-ICR) pulsed valve experiments are complicated by the pressure changes which occur rapidly after the opening of the pulsed valve. A method is described here to overcome that complication. The time-dependent number density n(t) is sampled by determining the total ion signal I(t(n)) in spectra resulting from pulsing the electron beam on at various delay times t, after opening the valve. The I(t(n)) are fit to an analytic function to give I(t) which can be integrated to give a kinetic variable comparable to pressure at fixed time or time at fixed pressure. A reactant ion isolated in the cell should disappear exponentially with integral(O)(tn) I(t) dt where the valve opens at time 0 admitting reactant neutral and the reactant ion concentration is sampled at time t(n). To obtain the rate constant from such an exponential decay the ionization cross section of the neutral must be known or estimated and the overall sensitivity of the instrument must be known. The latter can be determined by examining a reaction of known rate constant. The procedure is illustrated for the reaction of Re-2(+) with cyclohexane. The implications of this treatment for other types of pulsed valve experiments are discussed.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 9 条
[1]   EMPIRICAL-METHODS FOR DETERMINATION OF IONIZATION GAUGE RELATIVE SENSITIVITIES FOR DIFFERENT GASES [J].
BARTMESS, JE ;
GEORGIADIS, RM .
VACUUM, 1983, 33 (03) :149-153
[2]   PULSED VALVE ADDITION OF COLLISION AND REAGENT GASES IN FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
CARLIN, TJ ;
FREISER, BS .
ANALYTICAL CHEMISTRY, 1983, 55 (03) :571-574
[3]  
CODY RB, 1985, ANAL CHIM ACTA, V178, P43
[4]   FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISAROW, MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 25 (02) :282-283
[5]  
COMISAROW MB, 1987, ACS SYM SER, V359, P1
[6]  
IKEZOE Y, 1987, GAS PHASE ION MOL RE
[7]  
Ridge D. P., 1987, STRUCTURE REACTIVITY, P1
[8]   PULSED VALVE INTERFACE FOR GAS-CHROMATOGRAPHY FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
SACK, TM ;
GROSS, ML .
ANALYTICAL CHEMISTRY, 1983, 55 (14) :2419-2421
[9]   PARAMETRIZATION OF THE ION-POLAR MOLECULE COLLISION RATE-CONSTANT BY TRAJECTORY CALCULATIONS [J].
SU, T ;
CHESNAVICH, WJ .
JOURNAL OF CHEMICAL PHYSICS, 1982, 76 (10) :5183-5185