COMPARATIVE-EVALUATION OF MODIFIED M-FC AND M-TEC MEDIA FOR MEMBRANE-FILTER ENUMERATION OF ESCHERICHIA-COLI IN WATER

被引:49
作者
CIEBIN, BW
BRODSKY, MH
EDDINGTON, R
HORSNELL, G
CHONEY, A
PALMATEER, G
LEY, A
JOSHI, R
SHEARS, G
机构
[1] ORILLIA PUBL HLTH LAB, ORILLIA, ON, CANADA
[2] ONTARIO MINIST ENVIRONM & ENERGY LAB SERV, ETOBICOKE, ON, CANADA
[3] ONTARIO MINIST ENVIRONM & ENERGY, THUNDER BAY REG LAB, THUNDER BAY, ON, CANADA
[4] ONTARIO MINIST ENVIRONM & ENERGY, LONDON REG LAB, LONDON, ON, CANADA
[5] ONTARIO MINIST ENVIRONM & ENERGY, KINGSTON REG LAB, KINGSTON, ON, CANADA
[6] DURHAM REG ENVIRONM LAB, PICKERING, ON, CANADA
[7] REG MUNICIPAL OTTAWA CARLTON ENVIRONM SERV DEPT, DIV WATER POLLUT CONTROL, GLOUCESTER, ON, CANADA
关键词
D O I
10.1128/AEM.61.11.3940-3942.1995
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Two media used to detect fecal coliforms in water by membrane filtration, m-FC and m-TEC, were modified and supplemented with the chromogenic substrate 5-bromo-6-chloro-3-indoyl-beta-D-glucuronide (BCIG) and were compared for quantitative recovery of Escherichia coli. Student's t test of data from 181 water samples of sewage, rivers, lakes, and wells did not demonstrate any statistically significant differences (P = 0.05) in the enumeration of E. coli with these media. Target colonies were confirmed to be E. coli at rates of 98.6 and 97.3% by using FC-BCIG and TEC-BCIG media, respectively. Glucuronidase-negative isolates of E. coli were encountered at the same frequency (6.0%) on both media. This collaborative study demonstrated that either modified basal medium could be used successfully for detection of E. coli in various nontreated waters within 24 h.
引用
收藏
页码:3940 / 3942
页数:3
相关论文
共 12 条
[1]  
[Anonymous], 1993, STANDARD METHODS EXA
[2]   MEMBRANE-FILTER METHOD FOR ENUMERATING ESCHERICHIA-COLI [J].
DUFOUR, AP ;
STRICKLAND, ER ;
CABELLI, VJ .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1981, 41 (05) :1152-1158
[3]   POTENTIAL USE OF MEMBRANE FILTERS AND A FLUOREGENIC REAGENT-BASED SOLID MEDIUM FOR THE ENUMERATION OF ESCHERICHIA-COLI IN FOODS [J].
FARBER, JM .
CANADIAN INSTITUTE OF FOOD SCIENCE AND TECHNOLOGY JOURNAL-JOURNAL DE L INSTITUT CANADIEN DE SCIENCE ET TECHNOLOGIE ALIMENTAIRES, 1986, 19 (01) :34-37
[4]   FLUOROGENIC ASSAYS FOR IMMEDIATE CONFIRMATION OF ESCHERICHIA-COLI [J].
FENG, PCS ;
HARTMAN, PA .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1982, 43 (06) :1320-1329
[5]   EVALUATION OF THE BETA-GLUCURONIDASE SUBSTRATE 5-BROMO-4-CHLORO-3-INDOLYL-BETA-D-GLUCURONIDE (X-GLUC) IN A 24-HOUR DIRECT PLATING METHOD FOR ESCHERICHIA-COLI [J].
FRAMPTON, EW ;
RESTAINO, L ;
BLASZKO, N .
JOURNAL OF FOOD PROTECTION, 1988, 51 (05) :402-404
[6]  
GELDREICH E. E., 1965, Journal of the American Water Works Association, V57, P208
[7]   EVALUATION OF INDOXYL-BETA-D-GLUCURONIDE AS A CHROMOGEN IN MEDIA SPECIFIC FOR ESCHERICHIA-COLI [J].
HAINES, JR ;
COVERT, TC ;
RANKIN, CC .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1993, 59 (08) :2758-2759
[8]   INDOXYL-BETA-D-GLUCURONIDE, A NOVEL CHROMOGENIC REAGENT FOR THE SPECIFIC DETECTION AND ENUMERATION OF ESCHERICHIA-COLI IN ENVIRONMENTAL-SAMPLES [J].
LEY, AN ;
BOWERS, RJ ;
WOLFE, S .
CANADIAN JOURNAL OF MICROBIOLOGY, 1988, 34 (05) :690-693
[9]   MEMBRANE FILTRATION DIFFERENTIATION OF ESCHERICHIA-COLI FROM COLIFORMS IN THE EXAMINATION OF WATER [J].
MATES, A ;
SHAFFER, M .
JOURNAL OF APPLIED BACTERIOLOGY, 1989, 67 (03) :343-346
[10]   A RAPID FLUOROGENIC METHOD FOR THE DETECTION OF ESCHERICHIA-COLI BY THE PRODUCTION OF BETA-GLUCURONIDASE [J].
SARHAN, HR ;
FOSTER, HA .
JOURNAL OF APPLIED BACTERIOLOGY, 1991, 70 (05) :394-400