MEASURED VERSUS PREDICTED VERTICAL DISPLACEMENT OF THE SACRUM DURING GAIT AS A TOOL TO MEASURE BIOMECHANICAL GAIT PERFORMANCE

被引:57
作者
KERRIGAN, DC
VIRAMONTES, BE
CORCORAN, PJ
LARAIA, PJ
机构
[1] SPAULDING REHABIL HOSP,BOSTON,MA
[2] HARVARD UNIV,SCH MED,DEPT CARDIOL,BOSTON,MA 02115
关键词
GAIT; REHABILITATION; BIOMECHANICS; TASK PERFORMANCE; ANALYSIS;
D O I
10.1097/00002060-199501000-00002
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
The vertical displacement of the sacrum during walking is proposed as an estimation of the overall biomechanical performance of walking, independent of cardiopulmonary factors. Vertical sacral displacement during walking was measured using an optoelectronic motion analysis system in 10 normal volunteers at variable speeds. Oxygen consumption was simultaneously measured. The actual vertical displacement of the sacrum, when correlated with body weight, reliably predicted oxygen consumption (r(2) = 0.91). The relationship between vertical sacral displacement and oxygen consumption persisted when controlling for the variables, velocity, square of velocity, cadence or stride length, each known to co-vary with cardiopulmonary performance, A mathematic model designed to predict the vertical displacement of the sacrum, based on sacral height and average stride length, was tested. The actual vertical sacral displacement correlated with predicted displacement (r = 0.94). Unilateral immobilization of each subject's knee resulted in a greater average vertical sacral displacement during gait than predicted. Comparing measured with predicted vertical sacral displacement may provide a clinically useful and specific overall assessment of biomechanical gait performance.
引用
收藏
页码:3 / 8
页数:6
相关论文
共 17 条
[1]   AN ALGORITHM FOR 3-D AUTOMATIC MOVEMENT DETECTION BY MEANS OF STANDARD TV CAMERAS [J].
BORGHESE, NA ;
FERRIGNO, G .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (12) :1221-1225
[2]  
CAVAGNA GA, 1983, J APPL PHYSIOL, V55, P607
[3]   SOURCES OF EXTERNAL WORK IN LEVEL WALKING AND RUNNING [J].
CAVAGNA, GA ;
THYS, H ;
ZAMBONI, A .
JOURNAL OF PHYSIOLOGY-LONDON, 1976, 262 (03) :639-657
[4]  
CAVAGNA GA, 1963, J APPL PHYSIOL, V18, P1
[5]  
CORCORAN P J, 1970, Archives of Physical Medicine and Rehabilitation, V51, P78
[6]   THE ENERGY-EXPENDITURE AND MECHANICAL ENERGY DEMAND IN WALKING [J].
COTES, JE ;
MEADE, F .
ERGONOMICS, 1960, 3 (1-4) :97-119
[7]   TECHNIQUE FOR THE EVALUATION OF DERIVATIVES FROM NOISY BIOMECHANICAL DISPLACEMENT DATA USING A MODEL-BASED BANDWIDTH-SELECTION PROCEDURE [J].
DAMICO, M ;
FERRIGNO, G .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (05) :407-415
[8]  
DEMPSTER WT, 1955, THESIS U MICHIGAN AN
[9]   ELITE - A DIGITAL DEDICATED HARDWARE SYSTEM FOR MOVEMENT ANALYSIS VIA REAL-TIME TV SIGNAL-PROCESSING [J].
FERRIGNO, G ;
PEDOTTI, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (11) :943-950
[10]  
GONZALEZ EG, 1974, ARCH PHYS MED REHAB, V55, P111