LONG-TERM DIFFUSIVE SAMPLING OF VOLATILE ORGANIC-COMPOUNDS IN INDOOR AIR

被引:36
作者
BROWN, VM
CRUMP, DR
GARDINER, D
YU, CWF
机构
[1] Materials, Building Research Establishmen, Watford, Herts
关键词
VOCS; DIFFUSIVE; INDOOR AIR; CHAMBERS;
D O I
10.1080/09593339309385348
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Measurements of the diffusive uptake rate of six volatile organic compounds (VOCs) by Perkin Elmer type adsorbent tubes packed with Tenax using an exposure period of 4 weeks is described. Environmental chambers are applied to generate appropriate standard atmospheres containing the VOCs of interest to which the diffusive samplers are exposed. The diffusive uptake rates derived show good agreement between tests and are in accordance with results of field trials in non-industrial indoor air previously reported. Compounds of higher volatility, such as benzene have a considerably lower diffusive uptake rate than compounds such as undecane and 1,2,4-trimethylbenzene. The diffusive samplers are used to measure the concentration of six VOCs in the living room and main bedroom in 100 homes using a 4 week exposure period. Outdoor concentrations are also recorded at 10 locations. Indoor concentrations exceed those outdoors and are similar to those reported in four other major studies.
引用
收藏
页码:771 / 777
页数:7
相关论文
共 12 条
[1]  
BROWN R, 1992, CLEAR AIR WORK NEW T, P142
[2]   MEASUREMENT OF VOLATILE ORGANIC-COMPOUNDS IN INDOOR AIR BY A PASSIVE TECHNIQUE [J].
BROWN, VM ;
CRUMP, DR ;
GARDINER, D .
ENVIRONMENTAL TECHNOLOGY, 1992, 13 (04) :367-375
[3]  
COLOMBO A, 1991, EUR1359O EN REP
[4]   PERFORMANCE OF A THERMALLY DESORBABLE DIFFUSION SAMPLER FOR PERSONAL AND INDOOR AIR MONITORING [J].
DEBORTOLI, M ;
KNOPPEL, H ;
PECCHIO, E ;
VISSERS, H .
ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) :427-434
[5]  
DEBORTOLI M, 1987, DIFFUSIVE SAMPLING, P375
[6]  
GLOVER JH, 1991, THERMAL DESORPTION I
[7]  
LAURENT AM, 1992, CLEAN AIR WORK, P384
[8]   DIFFUSION COEFFICIENTS OF SOME ORGANIC AND OTHER VAPORS IN AIR [J].
LUGG, GA .
ANALYTICAL CHEMISTRY, 1968, 40 (07) :1072-&
[9]  
1992, DIFFUSIVE MONITOR CR
[10]  
1985, MDHS43 HLTH SAF EX