ANODIC-STRIPPING VOLTAMMETRY OF LEAD USING A COPPER-MERCURY FILM ELECTRODE

被引:30
作者
GUNASINGHAM, H
DALANGIN, RR
机构
[1] Department of Chemistry, National University of Singapore, Kent Ridge Crescent
关键词
ANODIC STRIPPING VOLTAMMETRY; COPPER MERCURY FILM ELECTRODE; LEAD;
D O I
10.1016/S0003-2670(00)80965-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The presence of copper increases the anodic stripping peak current of lead at bare glassy carbon and mercury film electrodes. Based on this, a preplated copper-mercury film electrode, prepared by the in situ plating of copper and mercury, can be employed to enhance the sensitivity for the determination of lead. When the molar concentration ratio of copper to mercury is high, a tenfold increase in sensitivity can be achieved compared with a pure mercury film electrode having the same film thickness. If the copper-mercury film is preplated freshly before each analysis, high precision is achievable, making it suitable for the routine monitoring of lead. The application of the copper-mercury film electrode to flow analysis is described.
引用
收藏
页码:309 / 313
页数:5
相关论文
共 23 条
[1]   DETERMINATION OF ZINC, CADMIUM, LEAD AND COPPER IN A SINGLE SEA-WATER SAMPLE BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
ABDULLAH, MI ;
BERG, BR ;
KLIMEK, R .
ANALYTICA CHIMICA ACTA, 1976, 84 (02) :307-317
[2]   STUDIES ON THE ANODIC-STRIPPING VOLTAMMETRY OF LEAD IN POLLUTED ESTUARINE WATERS [J].
ACEBAL, SA ;
REBELLO, AD .
ANALYTICA CHIMICA ACTA, 1983, 148 (APR) :71-78
[3]   DETERMINATION OF SELENIUM, COPPER, LEAD AND CADMIUM IN BIOLOGICAL-MATERIALS BY DIFFERENTIAL PULSE STRIPPING VOLTAMMETRY [J].
ADELOJU, SB ;
BOND, AM ;
HUGHES, HC .
ANALYTICA CHIMICA ACTA, 1983, 148 (APR) :59-69
[4]  
[Anonymous], 1985, STRIPPING ANAL PRINC
[5]   DETERMINATION OF HEAVY-METALS IN REAL SAMPLES BY ANODIC-STRIPPING VOLTAMMETRY WITH MERCURY MICROELECTRODES .2. APPLICATION TO RAIN AND SEA WATERS [J].
DANIELE, S ;
BALDO, MA ;
UGO, P ;
MAZZOCCHIN, GA .
ANALYTICA CHIMICA ACTA, 1989, 219 (01) :19-26
[6]   DETERMINATION OF HEAVY-METALS IN REAL SAMPLES BY ANODIC-STRIPPING VOLTAMMETRY WITH MERCURY MICROELECTRODES .1. APPLICATION TO WINE [J].
DANIELE, S ;
BALDO, MA ;
UGO, P ;
MAZZOCCHIN, GA .
ANALYTICA CHIMICA ACTA, 1989, 219 (01) :9-18
[7]   ANODIC-STRIPPING VOLTAMMETRIC DETERMINATION OF TRACE LEAD WITH A NAFION CROWN-ETHER FILM ELECTRODE [J].
DONG, SJ ;
WANG, YD .
TALANTA, 1988, 35 (10) :819-821
[8]   THE DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY OF COPPER AND LEAD AND THEIR DETERMINATION IN EDTA EXTRACTS OF SOILS WITH THE MERCURY FILM GLASSY-CARBON ELECTRODE [J].
EDMONDS, TE ;
GUOGANG, P ;
WEST, TS .
ANALYTICA CHIMICA ACTA, 1980, 120 (NOV) :41-53
[9]   THE GENERALIZED STANDARD ADDITION METHOD - INTERMETALLIC INTERFERENCES IN ANODIC-STRIPPING VOLTAMMETRY [J].
GERLACH, RW ;
KOWALSKI, BR .
ANALYTICA CHIMICA ACTA, 1982, 134 (JAN) :119-127
[10]   DETERMINATION OF DIFFUSION-COEFFICIENT AND CONCENTRATION OF GOLD IN MERCURY BASED ON PRE-PEAK FORMATION IN REDUCTION OF ZINC(II) AT HANGING GOLD AMALGAM DROP ELECTRODES [J].
GUMINSKI, C ;
GALUS, Z .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1977, 83 (01) :139-150