MEASUREMENT OF ORGANIC VAPORS AT SUB-TLV CONCENTRATIONS USING FAST GAS-CHROMATOGRAPHY

被引:12
作者
MOURADIAN, RF
LEVINE, SP
SACKS, RD
SPENCE, MW
机构
[1] UNIV MICHIGAN,DEPT ENVIRONM & IND HLTH,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN,DEPT CHEM,ANN ARBOR,MI 48109
[3] DOW CHEM CO USA,ANALYT & ENVIRONM CHEM,MIDLAND,MI 48674
来源
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL | 1990年 / 51卷 / 02期
关键词
D O I
10.1080/15298669091369385
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Gas chromatography usually is considered too slow a method to be useful for real-time or near real-time monitoring. If the chromatographic system is optimized for speed, however, it is possible to reduce retention times significantly. Recently, a fast gas chromatograph (GC) was described that allows many simple separations to be completed in 10 sec or less. The system features a gas-cooled, electrically heated, capillary cold trap that focuses the sample as an extremely narrow band at the front of the column. In this study the fast GC was used to measure the concentrations of benzene, toluene, and xylene in test atmospheres generated in the laboratory. The measurements then were compared to simultaneous measurements made with a conventional GC. At concentrations ranging from the threshold limit value (TLV®) to one-tenth of the TLV, the fast GC decreased retention times by a factor of 10- to 100-fold relative to the conventional GC, with no loss of precision or accuracy. These results indicate that it may be feasible to develop a high-speed monitoring system based on a GC design similar to the one in this study. © 1990, Taylor & Francis Group, LLC. All rights reserved.
引用
收藏
页码:90 / 95
页数:6
相关论文
共 14 条
[1]  
Desty D.H., 1962, GAS CHROMATOGRAPHY
[2]  
DESTY DH, 1965, ADV CHROMATOGR, V1, P199
[3]   ELECTRICALLY HEATED COLD TRAP INLET SYSTEM FOR HIGH-SPEED GAS-CHROMATOGRAPHY [J].
EWELS, BA ;
SACKS, RD .
ANALYTICAL CHEMISTRY, 1985, 57 (14) :2774-2779
[4]   INFLUENCE OF INSTRUMENTAL CONTRIBUTIONS ON APPARENT COLUMN EFFICIENCY IN HIGH-SPEED GAS-CHROMATOGRAPHY [J].
GASPAR, G ;
ANNINO, R ;
VIDALMADJAR, C ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1512-1518
[5]   STUDY IN HIGH-SPEED GAS-CHROMATOGRAPHY .1. INJECTIONS OF NARROW SAMPLE PLUGS [J].
GASPAR, G ;
ARPINO, P ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1977, 15 (07) :256-261
[6]   IMPROVEMENT OF SPEED OF SEPARATION IN PACKED-COLUMN GAS-CHROMATOGRAPHY [J].
JONKER, RJ ;
POPPE, H ;
HUBER, JFK .
ANALYTICAL CHEMISTRY, 1982, 54 (14) :2447-2456
[7]   COLLECTION AND ANALYSIS OF HAZARDOUS ORGANIC EMISSIONS [J].
KROST, KJ ;
PELLIZZARI, ED ;
WALBURN, SG ;
HUBBARD, SA .
ANALYTICAL CHEMISTRY, 1982, 54 (04) :810-817
[8]   ELECTRICALLY HEATED COLD TRAP INLET SYSTEM FOR COMPUTER-CONTROLLED HIGH-SPEED GAS-CHROMATOGRAPHY [J].
LANNING, LA ;
SACKS, RD ;
MOURADIAN, RF ;
LEVINE, SP ;
FOULKE, JA .
ANALYTICAL CHEMISTRY, 1988, 60 (18) :1994-1996
[9]  
MOURADIAN RF, 1988, MAY AM IND HYG C SAN
[10]   INCREASED SPEED OF ANALYSIS IN ISOTHERMAL AND TEMPERATURE-PROGRAMMED CAPILLARY GAS-CHROMATOGRAPHY BY REDUCTION OF THE COLUMN INNER DIAMETER [J].
SCHUTJES, CPM ;
VERMEER, EA ;
RIJKS, JA ;
CRAMERS, CA .
JOURNAL OF CHROMATOGRAPHY, 1982, 253 (01) :1-16