VOLUME T1-WEIGHTED GRADIENT ECHO MRI IN MULTIPLE-SCLEROSIS PATIENTS

被引:13
作者
SHAH, M
ROSS, JS
VANDYKE, C
RUDICK, RA
GOODKIN, DE
OBUCHOWSKI, N
MODIC, MT
机构
[1] CLEVELAND CLIN EDUC FDN,DIV RADIOL,9500 EUCLID AVE,CLEVELAND,OH 44106
[2] CLEVELAND CLIN EDUC FDN,DIV NEUROL,CLEVELAND,OH 44106
关键词
MULTIPLE SCLEROSIS; MAGNETIC RESONANCE IMAGING; TECHNIQUES; BRAIN; DEMYELINATION;
D O I
10.1097/00004728-199209000-00012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional (3D) volume turbo fast low angle shot (FLASH) techniques have become available which produce heavily T1-weighted images, similar to inversion recovery scans, utilizing the appropriate flip angle and inversion time. The purpose of this study was to compare the sensitivity of a rapid volume gradient echo technique [3D magnetization prepared rapid acquisition gradient echo (MP RAGE)] in identifying multiple sclerosis (MS) plaques with a conventional T2-weighted spin echo (SE) sequence. Ten patients with clinical MS were evaluated. Patients underwent a routine examination consisting of an axial T2-weighted SE sequence (2,500,22/90) and a coronal 3D MP RAGE, 10/4/10, acquired as 128 two mm partitions. In six patients, area measurements of 22 plaques were determined on both the axial T2-weighted SE examinations and the axial reformatted MP RAGE examinations. The overall number of plaques utilizing each technique was approximately the same. One hundred twenty-two plaques were visualized for the 3D MP RAGE sequence, and 128 plaques for the T2-weighted SE sequence. There were differences in detection of plaques in different regions, with plaques in gray matter better demonstrated utilizing the conventional T2-weighted SE sequence. Plaques in the corpus callosum, pons, and brachia pontis were better demonstrated utilizing 3D MP RAGE. No significant difference was found between the areas measured on the MP RAGE sequence and on the T2-weighted SE sequence. Three-dimensional MP RAGE provides a sensitive and complementary method to conventional T2-weighted SE sequences in the evaluation of patients with MS.
引用
收藏
页码:731 / 736
页数:6
相关论文
共 14 条
[1]   TOPOLOGICAL CHARACTERISTICS OF BRAIN-STEM LESIONS IN CLINICALLY DEFINITE AND CLINICALLY PROBABLE CASES OF MULTIPLE-SCLEROSIS - AN MRI-STUDY [J].
BRAININ, M ;
REISNER, T ;
NEUHOLD, A ;
OMASITS, M ;
WICKE, L .
NEURORADIOLOGY, 1987, 29 (06) :530-534
[2]   MP RAGE - A 3-DIMENSIONAL, T1-WEIGHTED, GRADIENT-ECHO SEQUENCE - INITIAL EXPERIENCE IN THE BRAIN [J].
BRANTZAWADZKI, M ;
GILLAN, GD ;
NITZ, WR .
RADIOLOGY, 1992, 182 (03) :769-775
[3]  
EDWARDS MK, 1989, P ANN M ASNR ORLANDO
[4]   ABNORMAL CORPUS-CALLOSUM - A SENSITIVE AND SPECIFIC INDICATOR OF MULTIPLE-SCLEROSIS [J].
GEANMARTON, AD ;
VEZINA, LG ;
MARTON, KI ;
STIMAC, GK ;
PEYSTER, RG ;
TAVERAS, JM ;
DAVIS, KR .
RADIOLOGY, 1991, 180 (01) :215-221
[5]  
GOODKIN DE, IN PRESS ARCH NEUROL
[6]  
HAASE A, 1989, P SOC MAGNETIC RESON, P5
[7]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[8]   CLINICAL-APPLICATIONS AND METHODOLOGICAL DEVELOPMENTS OF THE RARE TECHNIQUE [J].
HENNIG, J ;
FRIEDBURG, H .
MAGNETIC RESONANCE IMAGING, 1988, 6 (04) :391-395
[9]   3-DIMENSIONAL MAGNETIZATION-PREPARED RAPID GRADIENT-ECHO IMAGING (3DMP-RAGE) [J].
MUGLER, JP ;
BROOKEMAN, JR .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (01) :152-157
[10]   CONTRAST MANIPULATION AND ARTIFACT ASSESSMENT OF 2D AND 3D RARE SEQUENCES [J].
MULKERN, RV ;
WONG, STS ;
WINALSKI, C ;
JOLESZ, FA .
MAGNETIC RESONANCE IMAGING, 1990, 8 (05) :557-566