INTRINSIC ISOTACHOPHORETIC PRECONCENTRATION IN CAPILLARY GEL-ELECTROPHORESIS OF DNA RESTRICTION FRAGMENTS

被引:29
作者
VANDERSCHANS, MJ
BECKERS, JL
MOLLING, MC
EVERAERTS, FM
机构
[1] Laboratory of Instrumental Analysis, Eindhoven University of Technology, 5600 MB Eindhoven
关键词
D O I
10.1016/0021-9673(95)00534-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reproducible migration times are required for accurate base-pair assignment of polymerase chain reaction (PCR) products in capillary gel electrophoresis (CGE). However, migration times are influenced by injection plug length and ionic strength of the sample. In this paper we introduce a new isotachophoresis (ITP)-CGE system where the transition from ITP to CGE is achieved by the mobility shift of DNA from free solution (ITP) to sieving gel buffer (CGE). With intrinsic isotachophoretic preconcentration in capillary gel electrophoresis (IICGE) large volume injections (up to 700 nl) are possible with accurate migration times in CGE independent of injection plug length or sample ionic strength.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 22 条
[1]   ISOTACHOPHORESIS WITH 2 LEADING IONS AND MIGRATION BEHAVIOR IN CAPILLARY ZONE ELECTROPHORESIS .2. MIGRATION BEHAVIOR IN CAPILLARY ZONE ELECTROPHORESIS [J].
BECKERS, JL ;
EVERAERTS, FM .
JOURNAL OF CHROMATOGRAPHY, 1990, 508 (01) :19-26
[2]   UV DETECTION IN CAPILLARY ZONE ELECTROPHORESIS PEAKS OR DIPS - THAT IS THE QUESTION [J].
BECKERS, JL .
JOURNAL OF CHROMATOGRAPHY A, 1994, 679 (01) :153-165
[3]   CAPILLARY ELECTROPHORESIS INSTRUMENTATION AS A BENCH-TOP VISCOMETER [J].
BELLO, MS ;
REZZONICO, R ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY A, 1994, 659 (01) :199-204
[4]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[5]   QUANTITATION OF POLYMERASE CHAIN-REACTION PRODUCTS BY CAPILLARY ELECTROPHORESIS USING LASER FLUORESCENCE [J].
BUTLER, JM ;
MCCORD, BR ;
JUNG, JM ;
WILSON, MR ;
BUDOWLE, B ;
ALLEN, RO .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 658 (02) :271-280
[6]  
Davis B.J., 1964, ANN NY ACAD SCI, V121, P321
[7]   DETERMINATION OF SUBSTANCES AT LOW CONCENTRATIONS IN COMPLEX-MIXTURES BY ISOTACHOPHORESIS WITH COLUMN COUPLING [J].
EVERAERTS, FM ;
VERHEGGEN, TPEM ;
MIKKERS, FEP .
JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB) :21-38
[8]  
EVERAERTS FM, 1976, ISOTACHOPHORESIS
[9]   ON-COLUMN TRANSIENT AND COUPLED COLUMN ISOTACHOPHORETIC PRECONCENTRATION OF PROTEIN SAMPLES IN CAPILLARY ZONE ELECTROPHORESIS [J].
FORET, F ;
SZOKO, E ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :3-12
[10]   SEPARATION OF DNA RESTRICTION FRAGMENTS BY HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS WITH LOW AND ZERO CROSS-LINKED POLYACRYLAMIDE USING CONTINUOUS AND PULSED ELECTRIC-FIELDS [J].
HEIGER, DN ;
COHEN, AS ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :33-48