COMPARISON OF OCULAB TONO-PEN READINGS OBTAINED FROM VARIOUS CORNEAL AND SCLERAL LOCATIONS

被引:19
作者
KHAN, JA [1 ]
DAVIS, M [1 ]
GRAHAM, CE [1 ]
TRANK, J [1 ]
WHITACRE, MM [1 ]
机构
[1] UNIV KANSAS,MED CTR,SCH MED,DEPT PHYSIOL,KANSAS CITY,KS 66103
关键词
D O I
10.1001/archopht.1991.01080100124057
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
When estimating intraocular pressure in patients who are uncooperative or who have central corneal disturbances, the physician may find it either impractical or undesirable to place the small tip of a portable electronic applanation tonometer (Tono-Pen) over the central cornea. To gauge better the usefulness of Tono-Pen readings obtained from various locations, we compared such readings measured through the central cornea, midperipheral cornea, limbal cornea, and sclera of 15 cannulated eye bank eyes. Mean Tono-Pen readings from the midperipheral and clear limbal cornea did not differ significantly from central corneal readings over a 10- to 35-mm Hg range of intraocular pressures and were within +/- 2.4 mm Hg of mean central corneal readings. Mean readings taken from the sclera, however, were 8.8 to 17.0 mm Hg higher than mean central corneal readings over the 10- to 40-mm Hg range. We concluded that multiple noncentral corneal readings with the Tono-Pen provided a useful approximation of intraocular pressure, whereas scleral readings did not.
引用
收藏
页码:1444 / 1446
页数:3
相关论文
共 20 条
[1]  
ARMALY MF, 1961, ARCH OPHTHALMOL-CHIC, V65, P415
[2]   THE TONO-PEN - A MANOMETRIC AND CLINICAL-STUDY [J].
BOOTHE, WA ;
LEE, DA ;
PANEK, WC ;
PETTIT, TH .
ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (09) :1214-1217
[3]   AN EVALUATION OF THE TONO-PEN FOR THE MEASUREMENT OF DIURNAL INTRAOCULAR-PRESSURE [J].
FARRAR, SM ;
MILLER, KN ;
SHIELDS, MB ;
STOUP, CM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 107 (04) :411-416
[4]  
FRENKEL RE, 1988, ARCH OPHTHALMOL-CHIC, V106, P751
[5]   COMPARISON OF INTRAOCULAR-PRESSURE MEASUREMENTS WITH THE OCULAB TONO-PEN VS MANOMETRY IN HUMANS SHORTLY AFTER DEATH [J].
HESSEMER, V ;
ROSSLER, R ;
JACOBI, KW .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 105 (06) :678-682
[6]   CLINICAL-EVALUATION OF THE OCULAB TONO-PEN [J].
HIGGINBOTHAM, EJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 105 (01) :101-101
[7]  
HINES MW, 1988, AM J OPHTHALMOL, V106, P174
[8]   GOLDMANN APPLANATION TONOMETRY IN PATIENTS WITH REGULAR CORNEAL ASTIGMATISM [J].
HOLLADAY, JT ;
ALLISON, ME ;
PRAGER, TC .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1983, 96 (01) :90-93
[9]  
KAO SF, 1987, OPHTHALMOLOGY, V94, P1541
[10]   TONO-PEN ESTIMATION OF INTRAOCULAR-PRESSURE THROUGH BANDAGE CONTACT-LENSES [J].
KHAN, JA ;
LAGRECA, BA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (04) :422-425