BACTERIAL-CONTAMINATION OF AIR AND SURGICAL WOUNDS DURING JOINT REPLACEMENT OPERATIONS - COMPARISON OF 2 DIFFERENT TYPES OF STAFF CLOTHING

被引:22
作者
SCHEIBEL, JH
JENSEN, I
PEDERSEN, S
机构
[1] Department of Clinical Microbiology, Copenhagen County Hospitals
关键词
SURGICAL CLOTHING; WOUND SAMPLING; BACTERIAL CONTAMINATION; JOINT REPLACEMENT;
D O I
10.1016/0195-6701(91)90220-3
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Compared with conventional surgical clothing, polypropylene coveralls reduced the bacterial contamination of the air of a conventionally ventilated operating room by 62%. The contamination of surgical wounds during joint replacement was also reduced, but not to a significant degree. Sixteen percent of the bacteria sampled from the wounds were resistant to the prophylactic antibiotic and the importance of a clean air system for performing joint replacement operations is stressed. The use of commercially available non-woven swabs for sampling bacteria from the surgical wound compared favourably with the use of specially prepared velvet pads. © 1991.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 13 条
[1]  
BERGMAN BR, 1985, SCAND J INFECT DIS, V17, P421
[2]   THE USE OF THE REUTER CENTRIFUGAL AIR SAMPLER FOR THE ESTIMATION OF BACTERIAL AIR COUNTS IN DIFFERENT HOSPITAL LOCATIONS [J].
CASEWELL, MW ;
DESAI, N ;
LEASE, EJ .
JOURNAL OF HOSPITAL INFECTION, 1986, 7 (03) :250-260
[3]  
HILL C, 1981, LANCET, V1, P795
[4]   AIR, ANTIBIOTICS AND SEPSIS IN REPLACEMENT JOINTS [J].
LIDWELL, OM .
JOURNAL OF HOSPITAL INFECTION, 1988, 11 :18-40
[5]   EFFECT OF ULTRACLEAN AIR IN OPERATING-ROOMS ON DEEP SEPSIS IN THE JOINT AFTER TOTAL HIP OR KNEE REPLACEMENT - A RANDOMIZED STUDY [J].
LIDWELL, OM ;
LOWBURY, EJL ;
WHYTE, W ;
BLOWERS, R ;
STANLEY, SJ ;
LOWE, D .
BRITISH MEDICAL JOURNAL, 1982, 285 (6334) :10-14
[6]  
NACKHLA LS, 1981, J HOSP INFECT, V2, P261
[7]   VELVET PAD SURFACE SAMPLING OF ANAEROBIC AND AEROBIC-BACTERIA - AN INVITRO LABORATORY MODEL [J].
RAAHAVE, D ;
FRIISMOLLER, A .
JOURNAL OF CLINICAL PATHOLOGY, 1982, 35 (12) :1356-1360
[8]  
SCHWARTZ JT, 1980, SURG GYNECOL OBSTET, V150, P507
[9]  
Whyte W, 1982, J Hosp Infect, V3, P123, DOI 10.1016/0195-6701(82)90004-4
[10]   SUGGESTED BACTERIOLOGICAL STANDARDS FOR AIR IN ULTRACLEAN OPERATING-ROOMS [J].
WHYTE, W ;
LIDWELL, OM ;
LOWBURY, EJL ;
BLOWERS, R .
JOURNAL OF HOSPITAL INFECTION, 1983, 4 (02) :133-139