CHARGE TRANSPORT-PROPERTIES OF UNDOPED SI LEC GAAS SOLID-STATE DETECTORS

被引:18
作者
BEAUMONT, SP
BERTIN, R
BOOTH, CN
BRUZZI, M
BUTTAR, C
CARRARESI, L
CINDOLO, F
COLOCCI, M
COMBLEY, FH
DAURIA, S
DEGENNARO, S
DELPAPA, D
DOGRU, M
EDWARDS, M
FIORI, F
FOSTER, F
FRANCESCATO, A
HOU, Y
HOUSTON, P
JONES, B
LYNCH, JG
LISOWSKI, B
MATHESON, J
NAVA, F
NUTI, M
OSHEA, V
PELFER, PG
PISCHEDDA, M
RAINE, C
SANTANA, J
SAUNDERS, I
SELLER, PH
SKILLIKORN, IO
SLOAN, T
SMITH, KM
TARTONI, N
TENHAVE, I
TURNBULL, RM
VINATTIERI, A
ZICHICHI, A
机构
[1] INFN,BOLOGNA,ITALY
[2] INFN,FLORENCE,ITALY
[3] RUTHERFORD APPLETON LAB,DIDCOT OX11 0QX,OXON,ENGLAND
[4] UNIV SHEFFIELD,DEPT PHYS,SHEFFIELD S10 2TN,S YORKSHIRE,ENGLAND
[5] UNIV SHEFFIELD,DEPT ELECT ENGN,SHEFFIELD S10 2TN,S YORKSHIRE,ENGLAND
[6] CERN,CH-1211 GENEVA 23,SWITZERLAND
[7] UNIV FLORENCE,DIPARTIMENTO FIS,I-50121 FLORENCE,ITALY
[8] UNIV GLASGOW,DEPT ELECT & ELECTR ENGN,GLASGOW G12 8QQ,SCOTLAND
[9] UNIV GLASGOW,DEPT PHYS & ASTRON,GLASGOW G12 8QQ,SCOTLAND
[10] UNIV LANCASTER,DEPT PHYS,LANCASTER LA1 4YW,ENGLAND
[11] UNIV MODENA,DIPARTIMENTO FIS,I-41100 MODENA,ITALY
关键词
D O I
10.1016/0168-9002(93)90371-N
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The GaAs detectors for minimum ionizing particles fabricated with commercial undoped SI GaAs show good quality as minimum ionizing particle detectors. A discussion is given of the present understanding of the charge transport mechanism in the detectors since it influences their charge collection efficiency.
引用
收藏
页码:313 / 318
页数:6
相关论文
共 17 条
[1]  
Beaumont S. P., 1991, Nuclear Physics B, Proceedings Supplements, V23A, P417, DOI 10.1016/0920-5632(91)90078-S
[2]  
BEAUMONT SP, 1991, IEEE NUCLEAR SCI S S
[3]  
BEAUMONT SP, 1991, P ELOISATRON WORKSHO
[4]  
BEAUMONT SP, 1991, 4TH SAN MIN TOP SEM
[5]  
BEAUMONT SP, 1991, P LHC WORKSHOP AACHE, V3, P244
[6]  
BEAUMONT SP, 1990, P S DETECTOR RES DEV, P169
[7]   A PRELIMINARY-STUDY OF GAAS SOLID-STATE DETECTORS FOR HIGH-ENERGY PHYSICS [J].
BERTIN, R ;
DAURIA, S ;
DELPAPA, C ;
FIORI, F ;
LISOWSKI, B ;
OSHEA, V ;
PELFER, PG ;
SMITH, K ;
ZICHICHI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 294 (1-2) :211-218
[8]   A PRELIMINARY-STUDY OF THE RESPONSE OF A GALLIUM-ARSENIDE DETECTOR TO ALPHA-PARTICLES [J].
BUTTAR, CM ;
COMBLEY, FH ;
DAWSON, I ;
DOGRU, M ;
HARRISON, M ;
HILL, G ;
HOU, Y ;
HOUSTON, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2) :208-209
[9]  
DELPAPA C, IN PRESS 20TH EL WOR
[10]   HIGH-RESOLUTION NUCLEAR RADIATION DETECTORS FROM EPITAXIAL N-GAAS [J].
EBERHARDT, JE ;
RYAN, RD ;
TAVENDAL.AJ .
APPLIED PHYSICS LETTERS, 1970, 17 (10) :427-+