THE VALUE OF THE LIVER-SPECIFIC SUPERPARAMAGNETIC CONTRAST-MEDIUM AMI-25 FOR THE DETECTION OF PRIMARY LIVER-TUMORS AND THEIR DIFFERENTIATION FROM METASTASES

被引:32
作者
VOGL, TJ
HAMMERSTINGL, R
PEGIOS, W
HAMM, B
EIBLEIBESFELDT, A
WOESSMER, B
LISSNER, J
FELIX, R
机构
[1] UNIV MUNICH,RADIOL KLIN,W-8000 MUNICH 70,GERMANY
[2] FREE UNIV BERLIN,KLINIKUM STEGLITZ,RADIOL KLIN,BERLIN,GERMANY
[3] UNIV MUNICH,CHIRURG KLIN INNENSTADT,W-8000 MUNICH 70,GERMANY
[4] KONTRASTMITTEL,PARIS,FRANCE
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1994年 / 160卷 / 04期
关键词
MRT; FOCAL LIVER DISEASES; SUPERPARAMAGNETIC CONTRAST MEDIA; TISSUE CHARACTERIZATION;
D O I
10.1055/s-2008-1032431
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The value of the superparamagnetic contrast medium AMI-25 and its clinical acceptability was investigated in a phase-III-multicenter study. 18 patients with primary and secondary hepatic tumours were. studied using T2- and T1-weighted spin-echo sequences, FATSAT sequences and FLASH-2-D-breathhold sequences, both before and after intravenous application of AMI-25 (0.2 mmol GE/ml 15 mmol/kg KG in 100 ml 5 % glucose infusion), using a 1.5 Tesla MRT (Magnetom 63 SP, Siemens). In 6 patients the MRT findings could be correlated with in vitro results within 30 minutes following surgical resection. In 8 patients a diagnosis of metastases was made. Amongst patients with primary liver tumours (FNH 6 cases, HCC 3 cases, adenomatosis 1 case) 3 of the 10 patients showed more lesions following the injection of contrast: similarly, in 4 patients of the 8 with secondary tumours contrast increased the number of visible lesions. The absence of contrast enhancement separated primary from secondary lesions. Amongst the patients with secondary liver tumours, in vitro correlation always showed more tumours than had been visualised whereas there was exact in vivo/in vitro correlation amongst patients with primary liver tumours.
引用
收藏
页码:319 / 328
页数:10
相关论文
共 30 条
[1]  
BACON BR, 1987, J LAB CLIN MED, V110, P164
[2]   LIVER-TUMORS IN CIRRHOSIS - EXPERIMENTAL-STUDY WITH SPIO-ENHANCED MR IMAGING [J].
CLEMENT, O ;
FRIJA, G ;
CHAMBON, C ;
SCHOUMANCLAYES, E ;
MOSNIER, JF ;
POUPON, MF ;
BALKAU, B .
RADIOLOGY, 1991, 180 (01) :31-36
[3]   RELAXATION EFFICACY OF PARAMAGNETIC AND SUPERPARAMAGNETIC MICROSPHERES IN LIVER AND SPLEEN [J].
FAHLVIK, AK ;
HOLTZ, E ;
KLAVENESS, J .
MAGNETIC RESONANCE IMAGING, 1990, 8 (04) :363-369
[4]   SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR IMAGING - PULSE SEQUENCE OPTIMIZATION FOR DETECTION OF LIVER-CANCER [J].
FRETZ, CJ ;
ELIZONDO, G ;
WEISSLEDER, R ;
HAHN, PF ;
STARK, DD ;
FERRUCCI, JT .
RADIOLOGY, 1989, 172 (02) :393-397
[5]   SUPERPARAMAGNETIC IRON-OXIDE - CLINICAL TIME-RESPONSE STUDY [J].
GANDON, Y ;
HEAUTOT, JF ;
BRUNET, F ;
GUYADER, D ;
DEUGNIER, Y ;
CARSIN, M .
EUROPEAN JOURNAL OF RADIOLOGY, 1991, 12 (03) :195-200
[6]   SUPERPARAMAGNETIC IRON-OXIDE PARTICLES - REPLY [J].
GORE, JC ;
MAJUMDAR, S .
RADIOLOGY, 1988, 169 (03) :657-658
[7]   CLINICAL-APPLICATION OF SUPERPARAMAGNETIC IRON-OXIDE TO MR IMAGING OF TISSUE PERFUSION IN VASCULAR LIVER-TUMORS [J].
HAHN, PF ;
STARK, DD ;
WEISSLEDER, R ;
ELIZONDO, G ;
SAINI, S ;
FERRUCCI, JT .
RADIOLOGY, 1990, 174 (02) :361-366
[8]   DIFFERENTIATION OF HEPATOCELLULAR CARCINOMAS FROM HYPERPLASTIC NODULES INDUCED IN RAT-LIVER WITH FERRITE-ENHANCED MR IMAGING [J].
KAWAMORI, Y ;
MATSUI, O ;
KADOYA, M ;
YOSHIKAWA, J ;
DEMACHI, H ;
TAKASHIMA, T .
RADIOLOGY, 1992, 183 (01) :65-72
[9]   PHARMACOKINETICS OF SUPERPARAMAGNETIC IRON-OXIDE MR CONTRAST AGENTS IN THE RAT [J].
MAJUMDAR, S ;
ZOGHBI, SS ;
GORE, JC .
INVESTIGATIVE RADIOLOGY, 1990, 25 (07) :771-777
[10]   QUANTITATION OF MR RELAXATION EFFECTS OF IRON-OXIDE PARTICLES IN LIVER AND SPLEEN [J].
MAJUMDAR, S ;
ZOGHBI, S ;
POPE, CF ;
GORE, JC .
RADIOLOGY, 1988, 169 (03) :653-655