DIGITAL MAMMOGRAPHY - M-CHANNEL QUADRATURE MIRROR FILTERS (QMFS) FOR MICROCALCIFICATION EXTRACTION

被引:24
作者
QIAN, W
CLARKE, LP
LI, HD
CLARK, R
SILBIGER, ML
机构
[1] UNIV S FLORIDA, COLL MED, DEPT RADIOL, TAMPA, FL 33612 USA
[2] UNIV S FLORIDA, H LEE MOFFIT CANC CTR & RES INST, TAMPA, FL 33612 USA
关键词
D O I
10.1016/0895-6111(94)90001-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multiresolution methods are reported for feature extraction in breast cancer screening using digital mammography. The initial application is directed at the detection of microcalcification clusters (MCCs). Quadrature mirror filter (QMF) banks, using both two and three channel are proposed for the first time for both multiresolution decomposition and reconstruction. These filters are specifically tailored for automatic extraction of MCCs. The QMF multiresolution methods are compared to two channel tree structured wavelet transforms (TSWTs) methods previously reported. The QMF filters are preceded by an advanced tree structured nonlinear filter for noise suppression, prior to feature extraction, in order to minimize the false positive (FP) detection rate in digital mammography. The relative performance of these methods were evaluated using both simulated images and fifteen representative digitized mammograms containing biopsy proven microcalcification clusters. Similar high sensitivity (true positive (TP) detection rate (100%) and high specificity (0.6 average false positive (FP) MCC's/image) were observed, substantially better than more traditional approaches using single scale filters. The three channel QMF method, however, demonstrated better detail preservation of MCC's extracted compared to the two channel method. Detail preservation is important for the characterization of MCC's or individual microcalcifications in cancer screening.
引用
收藏
页码:301 / 314
页数:14
相关论文
共 29 条
[1]  
CLARKE LP, 1994, MULTILAYER FEEDFORWA
[2]  
CLARKE LP, 1992, P S COMPUTER ASSISTE, P116
[3]  
CLARKE LP, IN PRESS CANCER LETT
[4]  
CLARKE LP, 1993, NASA C PUBLICATION, V3191, P63
[5]  
DOI K, 1992, SEMIN ULTRASOUND CT, V13, P140
[6]  
GIGER ML, 1992, SYLLABUS CATEGORICAL, P257
[7]   IMAGE SEGMENTATION IN DIGITAL MAMMOGRAPHY - COMPARISON OF LOCAL THRESHOLDING AND REGION GROWING ALGORITHMS [J].
KALLERGI, M ;
WOODS, K ;
CLARKE, LP ;
QIAN, W ;
CLARK, RA .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1992, 16 (05) :323-331
[8]  
KARSSEMEIJER N, 1991, 12 INT C INF PROC ME, P227
[9]  
KEGELMEYER WP, 1993, P SOC PHOTO-OPT INS, V1905, P787
[10]  
LAINE A, 1993, P SOC PHOTO-OPT INS, V1905, P521, DOI 10.1117/12.148666