摘要
The feasibility of replacing a conventional mass spectrometer (MS) with a specially modified multicomponent (O-2, CO2, Freon 22, and SF6) acoustic infrared and paramagnetic (IR/PM) gas analyzer in inert gas-rebreathing and metabolic gas exchange measurements has been investigated. Rebreathing variables were determined simultaneously with the MS and IR/PM analyzers in duplicate measurements at rest and during submaximal exercise in 10 subjects. The differences (means +/- SD, IR/PM - MS) were 0.028 +/- 0.048 liters [functional residual capacity (FRC)], 0.18 +/- 0.38 l/min [cardiac output (Qc)], -0.006 +/- 0.030 l/min [O-2 consumption (VO2)], and -33 +/- 108 ml [combined lung tissue and capillary blood volume (Vti,c)]. The coefficients of variation on repeated estimates were 5.8% (FRC), 5.4% (Qc), 6.2% (VO2), and 17% (Vti,c) with the IR/PM analyzer and 5.9% (FRC), 4.2% (Qc), 5.0% (ire,), and 9.8% (Vti,c) with the MS. The differences (IR/PM-MS) obtained in mixed-expirate measurements were -0.006 +/- 0.020 l/min (VO2) and 0.020 +/- 0.021 l/min (CO2 production). Breath-by-breath estimates of VO2 and CO2 production with the IR/PM analyzer were, on average, 2.4 and 4.4% higher than the MS estimates, respectively. Our results demonstrate that the IR/PM gas analyzer, when appropriately modified, can substitute for a complex MS in a variety of noninvasive pulmonary gas exchange measurements.
引用
收藏
页码:2832 / 2839
页数:8
相关论文
共 23 条
[1]   CORRECTIONS FOR THE RESPONSE-TIME AND DELAY OF MASS SPECTROMETERS [J].
ARIELI, R ;
VANLIEW, HD .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 51 (06) :1417-1422
[2]   THE CARDIAC OUTPUT IN REST AND WORK DETERMINED SIMULTANEOUSLY BY THE ACETYLENE AND THE DYE INJECTION METHODS [J].
ASMUSSEN, E ;
NIELSEN, M .
ACTA PHYSIOLOGICA SCANDINAVICA, 1953, 27 (2-3) :217-230
[3]   BREATH-BY-BREATH MEASUREMENT OF TRUE ALVEOLAR GAS-EXCHANGE [J].
BEAVER, WL ;
LAMARRA, N ;
WASSERMAN, K .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 51 (06) :1662-1675
[4]   ASPECTS OF ONLINE DIGITAL INTEGRATION OF PULMONARY GAS TRANSFER [J].
BERNARD, TE .
JOURNAL OF APPLIED PHYSIOLOGY, 1977, 43 (02) :375-378
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
BONDEPETERSEN F, 1980, AVIAT SPACE ENVIR MD, V51, P1214
[7]   DETERMINATION OF PULMONARY PARENCHYMAL TISSUE VOLUME AND PULMONARY CAPILLARY BLOOD FLOW IN MAN [J].
CANDER, L ;
FORSTER, RE .
JOURNAL OF APPLIED PHYSIOLOGY, 1959, 14 (04) :541-551
[8]   MEASUREMENT OF METABOLIC GAS-EXCHANGE AND MINUTE VOLUME BY MASS-SPECTROMETRY ALONE [J].
DAVIES, NJH ;
DENISON, DM .
RESPIRATION PHYSIOLOGY, 1979, 36 (02) :261-267
[9]   LUNG FUNCTION STUDIES .2. THE RESPIRATORY DEAD SPACE [J].
FOWLER, WS .
AMERICAN JOURNAL OF PHYSIOLOGY, 1948, 154 (03) :405-416
[10]   WATER VAPOR PRESSURE OF END-TIDAL AIR OF NORMALS AND CHRONIC BRONCHITICS [J].
GREEN, ID ;
NESARAJA.MS .
JOURNAL OF APPLIED PHYSIOLOGY, 1968, 24 (02) :229-&