3-BODY ABRASIVE WEAR BEHAVIOR OF ORTHOPEDIC IMPLANT BEARING SURFACES FROM TITANIUM DEBRIS

被引:26
作者
POGGIE, RA
MISHRA, AK
DAVIDSON, JA
机构
[1] Orthopaedic Research Department, Smith and Nephew Richards Inc., Memphis, 38116, TN
关键词
D O I
10.1007/BF00058970
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The abrasive wear behaviour of several orthopaedic bearing materials was characterized for fully conformal, reciprocating sliding contact against ultra-high molecular weight polyethylene (UHMWPE). The bearing surfaces investigated were nitrogen ion implanted Ti-6Al-4V, TiN coated Ti-6Al-4V, Ti-6Al-4V, F-799 Co-Cr-Mo, yttria-stabilized zirconia and a Zr-2.5Nb alloy with a zirconia ceramic surface. The third-body debris was introduced as either Ti-6Al-4V particles or oxidized titanium powder (black debris). The wear tests were performed In deionized water with the third-body debris entrapped between the UHMWPE and the hard bearing surface. Surface profilometry measurements, scanning electron microscopy (SEM) and optical microscopy showed the severity of damage to the hard bearing surfaces to increase with decreasing hardness. The abrasion damage to the UHMWPE increased as the roughness of the opposing, hard bearing surface increased. Surface profilometry and energy dispersive spectroscopy (EDS) also showed oxidized titanium (black debris) to form an adherent transfer layer on all of the hard bearing surfaces. Nitrogen ion implantation of Ti-6Al-4V was ineffective in reducing wear of both the Ti-6Al-4V substrate and the UHMWPE. Solid yttria-stabilized zirconia and zirconia-coated Zr-2.5Nb showed no evidence of abrasion damage and produced the least amount of UHMWPE wear. These results are attributed to the high hardness and excellent wear resistance of zirconia and the excellent wettability of ZrO2 due to its relatively high ionic character in comparison to metals and covalently bonded compounds.
引用
收藏
页码:387 / 392
页数:6
相关论文
共 24 条
[1]  
[Anonymous], 1980, WEAR CONTROL HDB
[2]  
Bowden F, 1964, FRICTION LUBRICATION
[3]   WEAR-ACCELERATED CORROSION OF TI-6AL-4V AND NITROGEN-ION-IMPLANTED TI-6AL-4V - MECHANISMS AND INFLUENCE OF FIXED-STRESS MAGNITUDE [J].
BUCHANAN, RA ;
RIGNEY, ED ;
WILLIAMS, JM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (03) :367-377
[4]  
BULLOUGH PG, 1973, HIP, P80
[5]  
CAMPBELL P, 1990, OCT ASTM S BIOC PART
[6]  
CLARKE I, 1990, OCT S BIOC PART IMPL
[7]  
DARKIN LS, 1953, PHYSICAL CHEM METALS, P79
[8]  
Dowson D., 1985, POLYM WEAR ITS CONTR
[9]   TRIBOCHEMICAL MECHANISM OF ALUMINA WITH WATER [J].
GATES, RS ;
HSU, SM ;
KLAUS, EE .
TRIBOLOGY TRANSACTIONS, 1989, 32 (03) :357-363
[10]  
GUALTIERI G, 1992, CLIN ORTHOPAEDICS, V282, P81