AMPEROMETRIC SENSOR FOR CHOLINE AND ACETYLCHOLINE BASED ON A PLATINUM-ELECTRODE MODIFIED BY A CO-CROSS-LINKED BIENZYMIC SYSTEM

被引:43
作者
GUERRIERI, A [1 ]
DEBENEDETTO, GE [1 ]
PALMISANO, F [1 ]
ZAMBONIN, PG [1 ]
机构
[1] UNIV BARI,DIPARTMENTO CHIM,I-70126 BARI,ITALY
关键词
BIOSENSOR; CHOLINE; ACETYLCHOLINE;
D O I
10.1039/an9952002731
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast-response and sensitive amperometric biosensor for choline and acetylcholine based on choline oxidase and acetylcholinesterase immobilized on a platinum electrode by co-crosslinking with bovine serum albumin and glutaraldehyde has been developed. The immobilization procedure proved fast and simple, not requiring dedicated manipulation. Detection limits mere in the sub-micromolar range and linearity extended over three concentration decades. After one month of discontinuous use, 70% of the initial sensitivity was still observed. The response time was around 1 s for both analytes making the developed biosensor a suitable detector for flow injection systems and high-performance liquid chromatography.
引用
收藏
页码:2731 / 2736
页数:6
相关论文
共 36 条
  • [1] ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .1. THEORY
    BARTLETT, PN
    WHITAKER, RG
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2): : 27 - 35
  • [2] ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE
    BARTLETT, PN
    WHITAKER, RG
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2): : 37 - 48
  • [3] NEUROTRANSMITTER-RELATED ENZYMES AND INDEXES OF HYPOXIA IN SENILE DEMENTIA AND OTHER ABIOTROPHIES
    BOWEN, DM
    SMITH, CB
    WHITE, P
    DAVISON, AN
    [J]. BRAIN, 1976, 99 (SEP) : 459 - 496
  • [4] CAMPANELLA L, 1991, ANN CHIM-ROME, V81, P639
  • [5] MASS-TRANSPORT AND REACTION KINETIC-PARAMETERS DETERMINED ELECTROCHEMICALLY FOR IMMOBILIZED GLUCOSE-OXIDASE
    CASTNER, JF
    WINGARD, LB
    [J]. BIOCHEMISTRY, 1984, 23 (10) : 2203 - 2210
  • [6] Cornish-Bowden A, 1976, PRINCIPLES ENZYME KI
  • [7] DETERMINATION OF ACETYLCHOLINE AND CHOLINE IN THE FEMTOMOLE RANGE BY MEANS OF HPLC, A POST-COLUMN ENZYME REACTOR, AND ELECTROCHEMICAL DETECTION
    DAMSMA, G
    VANBUEREN, DL
    WESTERINK, BHC
    HORN, AS
    [J]. CHROMATOGRAPHIA, 1987, 24 : 827 - 831
  • [8] DAVIES P, 1976, LANCET, V2, P1403
  • [9] Davis K., 1979, BRAIN ACETYLCHOLINE
  • [10] AMPEROMETRIC SENSORS FOR PEROXIDE, CHOLINE, AND ACETYLCHOLINE BASED ON ELECTRON-TRANSFER BETWEEN HORSERADISH-PEROXIDASE AND A REDOX POLYMER
    GARGUILO, MG
    HUYNH, N
    PROCTOR, A
    MICHAEL, AC
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (05) : 523 - 528