AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY FOR THE QUANTITATIVE-DETERMINATION OF ANTI-D IN PLASMA SAMPLES AND IMMUNOGLOBULIN PREPARATIONS

被引:6
作者
HIRVONEN, M
TERVONEN, S
PIRKOLA, A
SIEVERS, G
机构
[1] Finnish Red Cross Blood Transfusion Service, Helsinki
关键词
D O I
10.1111/j.1423-0410.1995.tb00370.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Here we present an enzyme-linked immunosorbent assay (ELISA) on microtiter plates for the quantitative determination of anti-D. This method is based on the solubilization of red blood cells sensitized with anti-D and the subsequent measurement of immunoglobulin G by ELISA. The measuring range of the assay is 40-5,000 IU/ml and the lowest quantifiable concentration in plasma is 0.5 IU/ml. The interassay relative standard deviation for concentrations above 130 IU/ml ranges from 3.2 to 8.1% and below 50 IU/ml from 10.5 to 19.7%. Comparison of ELISA with automated hemagglutination shows that the results of the two assays correlate well: r = 0.992, n = 26. The assay was validated for donor plasma samples and anti-D immunoglobulin preparations and it can also be used in assessing the severity of Rh (D) hemolytic disease during pregnancy.
引用
收藏
页码:341 / 346
页数:6
相关论文
共 22 条
[1]   EFFECT OF DITHIOTHREITOL TREATMENT OF PLASMA ON AUTOMATED ANTI-D ASSAY [J].
ASHFORD, PR ;
LOVE, M ;
PAYNE, SG .
VOX SANGUINIS, 1985, 49 (02) :121-125
[2]   TRANSFORMING SIGNALS INTO QUANTITATIVE VALUES AND MATHEMATICAL TREATMENT OF DATA [J].
BAUD, M ;
MERCIER, M ;
CHATELAIN, F .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1991, 51 :120-130
[3]   MATERNAL ANTI-D CONCENTRATIONS AND OUTCOME IN RHESUS HEMOLYTIC-DISEASE OF THE NEWBORN [J].
BOWELL, P ;
WAINSCOAT, JS ;
PETO, TEA ;
GUNSON, HH .
BRITISH MEDICAL JOURNAL, 1982, 285 (6338) :327-329
[4]  
CAMPBELL EJ, 1991, MED LAB SCI, V48, P52
[5]   ANTENATAL TESTS IN THE DIAGNOSIS AND ASSESSMENT OF SEVERITY OF HEMOLYTIC-DISEASE (HD) OF THE FETUS AND NEWBORN (HDN) [J].
CONTRERAS, M .
VOX SANGUINIS, 1994, 67 :207-210
[6]  
GILMAN GE, 1982, AM J CLIN PATHOL, V77, P206
[7]   EVALUATION OF STANDARD PARAMETERS TO PREDICT EXCHANGE TRANSFUSIONS IN THE ERYTHROBLASTOTIC NEWBORN [J].
GOTTVALL, T ;
HILDEN, JO ;
SELBING, A .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1994, 73 (04) :300-306
[8]   AN ENZYME-LINKED ANTIGLOBULIN-TEST TO DETECT RED-CELL GLOBULINS AFTER GLUTARALDEHYDE FIXATION [J].
GREENWALT, TJ ;
DUMASWALA, UJ ;
SIONGCO, A ;
DOMINO, MM .
VOX SANGUINIS, 1992, 63 (04) :262-267
[9]   CORRELATION OF SEROLOGICAL, QUANTITATIVE AND CELL-MEDIATED FUNCTIONAL ASSAYS OF MATERNAL ALLOANTIBODIES WITH THE SEVERITY OF HEMOLYTIC-DISEASE OF THE NEWBORN [J].
HADLEY, AG ;
KUMPEL, BM ;
LEADER, KA ;
POOLE, GD ;
FRASER, ID .
BRITISH JOURNAL OF HAEMATOLOGY, 1991, 77 (02) :221-228
[10]   A SENSITIVE ENZYME-IMMUNOASSAY FOR THE MEASUREMENT OF LOW CONCENTRATIONS OF IGA [J].
HIRVONEN, M ;
KOSKINEN, S ;
TOLO, H .
JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 163 (01) :59-65