FACTORS AFFECTING THE IONIZATION EFFICIENCY OF QUATERNARY AMMONIUM-COMPOUNDS IN ELECTROSPRAY IONSPRAY MASS-SPECTROMETRY

被引:44
作者
RAFFAELLI, A [1 ]
BRUINS, AP [1 ]
机构
[1] UNIV GRONINGEN,CTR PHARM,9713 AW GRONINGEN,NETHERLANDS
关键词
D O I
10.1002/rcm.1290050605
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A series of quaternary ammonium salts was analysed by the ionspray technique under different conditions in order to study the influence of some important factors on the ionization efficiency. The factors taken into account were droplet charging, sample ion, counter ion, solvent composition, and concentration. Measurement of the spray current leaving the nebulizer has shown that the spray current increases linearly with sample concentration up to at least 50 pmol/mu-L. The measured spray current is approximately 30% of the calculated current corresponding to a given concentration of quarternary ammonium ions in solution leaving the nebulizer at a given flow rate. The results obtained show that tetraalkylammonium salts give the best sensitivity with no influence of sample-ion shape or counter ion. The introduction of other functional groups in the quaternary ammonium ion decreases the sensitivity. The dynamic range for full-scan mass spectra of the compounds studied appears to be linear for concentrations from 0.1 pmol/mu-L (10(-7) M) up to 10 pmol/mu-L (10(-5)M).
引用
收藏
页码:269 / 275
页数:7
相关论文
共 22 条
[1]  
ALEKSANDROV ML, 1984, ZH ANAL KHIM, V40, P1570
[2]  
Bailey A. G., 1986, Atomisation and Spray Technology, V2, P95
[3]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[4]  
BRUINS AP, 1988, 36TH P ASMS C MASS S, P1241
[5]   SPACE-CHARGE-DOMINATED MASS-SPECTROMETRY ION SOURCES - MODELING AND SENSITIVITY [J].
BUSMAN, M ;
SUNNER, J ;
VOGEL, CR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (01) :1-10
[6]   COMPARISON OF THERMOSPRAY AND ION SPRAY MASS-SPECTROMETRY IN AN ATMOSPHERIC-PRESSURE ION-SOURCE [J].
COVEY, TR ;
BRUINS, AP ;
HENION, JD .
ORGANIC MASS SPECTROMETRY, 1988, 23 (03) :178-186
[7]   MASS-SPECTROSCOPY AT HIGH MASS [J].
DERRICK, PJ .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 324 (05) :486-491
[8]  
DOLE M, 1978, ADV CHEM SER, V125, P73
[9]   ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[10]   ELECTROSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
HIRAOKA, K ;
KUDAKA, I .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (12) :519-526