DEHYDRATION AND ORTHOSTATIC VITAL SIGNS IN WOMEN WITH HYPEREMESIS GRAVIDARUM

被引:19
作者
JOHNSON, DR [1 ]
DOUGLAS, D [1 ]
HAUSWALD, M [1 ]
TANDBERG, D [1 ]
机构
[1] OREGON HLTH SCI UNIV,SCH MED,DEPT EMERGENCY MED,DIV TOXICOL,PORTLAND,OR 97201
关键词
HYPEREMESIS GRAVIDARUM; PREGNANCY; ORTHOSTATIC VITAL SIGNS; TILT TEST; RECEIVER OPERATING CHARACTERISTIC CURVES; BLOOD PRESSURE;
D O I
10.1111/j.1553-2712.1995.tb03620.x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To assess the hydration status of women presenting to an ED with hyperemesis gravidarum and to determine whether clinically relevant changes in orthostatic vital signs occur. Methods: A convenience sample of 23 pregnant women who had hyperemesis gravidarum, with each patient serving as her own control. The study took place in the ED observation unit of an urban teaching hospital. Women who had pregnancies of less than or equal to 16 weeks' gestation who had been vomiting for at least 24 hours were included. Supine and standing pulse rates and blood pressures (BPs) were measured sequentially after 5 minutes in each position. Patient weight and urine specific gravity (SG) also were recorded. After 6 L of lactated Ringer's solution was infused over a 12-hour period, the same measurements were repeated. Pre- and posthydration changes were analyzed using the paired t-test. Results: The mean treatment weight gain as a percentage of the total body weight was 5.6% +/- 2.2% (mean +/- SD). The urine SG decreased from 1.027 +/- 0.004 to 1.008 +/- 0.003 (p < 0.001). The mean change in systolic BP upon assuming the standing position was -8.3 +/- 12.7 mm Hg before hydration vs 2.9 +/- 7.8 mm Hg after hydration (p < 0.001). The corresponding change in mean diastolic BP was 3.7 +/- 10.9 mm Hg before hydration vs 8.6 +/- 10.9 mm Hg after hydration (p = 0.12). The mean change in pulse rate upon standing was 26.8 +/- 14.5 beats/min before hydration vs 14.5 +/- 10.1 beats/min after hydration (p = 0.002). Conclusions: Women who present to the ED with hyperemesis gravidarum are significantly dehydrated and experience measurable improvement in postural pulse rate and systolic BP changes with rehydration. However, the presenting orthostatic changes lack sufficient sensitivity to be effectively used as quantitative screening tests for dehydration.
引用
收藏
页码:692 / 697
页数:6
相关论文
共 17 条
[1]  
ABELL TL, 1992, GASTROENTEROL CLIN N, V21, P835
[2]   ORTHOSTATIC VITAL SIGNS - VARIATION WITH AGE, SPECIFICITY, AND SENSITIVITY IN DETECTING A 450-ML BLOOD-LOSS [J].
BARAFF, LJ ;
SCHRIGER, DL .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1992, 10 (02) :99-103
[4]   MAXIMUM-LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL-DETECTION THEORY AND DETERMINATION OF CONFIDENCE INTERVALS - RATING-METHOD DATA [J].
DORFMAN, DD ;
ALF, E .
JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1969, 6 (03) :487-&
[5]   Hyperemesis gravidarum - A clinical study of 396 cases [J].
Fitzgerald, JE ;
Webster, A .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1938, 36 :460-466
[6]   EVALUATION OF THE TILT TEST IN CHILDREN [J].
FUCHS, SM ;
JAFFE, DM .
ANNALS OF EMERGENCY MEDICINE, 1987, 16 (04) :386-390
[7]  
GREEN DM, 1948, SURG GYNECOL OBSTET, V8, P145
[8]   MATERNAL WEIGHT-LOSS ASSOCIATED WITH HYPEREMESIS GRAVIDARUM - A PREDICTOR OF FETAL-OUTCOME [J].
GROSS, S ;
LIBRACH, C ;
CECUTTI, A .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1989, 160 (04) :906-909
[9]  
Knopp R, 1980, ANN EMERG MED, V9, P29
[10]   ORTHOSTATIC VITAL SIGNS IN EMERGENCY DEPARTMENT PATIENTS [J].
KOZIOLMCLAIN, J ;
LOWENSTEIN, SR ;
FULLER, B .
ANNALS OF EMERGENCY MEDICINE, 1991, 20 (06) :606-610