A comparison of two transcutaneous monitors for the measurement of arterial PO2 and PCO2 in neonates

被引:17
作者
Carter, B [1 ]
Hochmann, M [1 ]
Osborne, A [1 ]
Nisbet, A [1 ]
Campbell, N [1 ]
机构
[1] ROYAL CHILDRENS HOSP,MELBOURNE,VIC,AUSTRALIA
关键词
monitoring; oxygen; carbon dioxide; transcutaneous;
D O I
10.1177/0310057X9502300610
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We examined the ability of two transcutaneous devices (Fastrac, Sensormedics Corporation, Yorba Linda, California, U.S.A. and Hewlett Packard M1018A, Hewlett Packard Component Monitoring System, Hewlett Packard, North Hollywood, U.S.A.) to measure arterial PCO2 and PO2 in neonates. Thirty-seven neonates had transcutaneous oxygen measured with the Hewlett Packard (HPO2 group), 38 neonates had transcutaneous carbon dioxide measured with the Hewlett Packard (HPCO2 group) and the Fastrac was used on 27 neonates (FTCO2 group). Both devices were operated with electrode temperatures of 43.5 degrees C although an additional ten subjects were studied using the Fastrac with an electrode temperature of 43.0 degrees C. The mean differences (transcutaneous-arterial) and upper and lower limits of agreement were calculated for each group. For the HPO2 group they were 3.78 mmHg (-12.23 to 19.80 mmHg), for the HPCO2 group they were 0.40 mmHg (-4.50 to 5.30 mmHg) and for the FTCO2 they were -0.96 mmHg (-7.85 to 5.92 mmHg). For the Fastrac group at an electrode temperature of 43.0 degrees C the mean difference and limits of agreement were -1.00 mmHg and -4.58 mmHg to 2.58 mmHg. The average sensitivity and specificity for both machines for the detection of hypocarbia were 82% and 92% respectively white for hypercarbia they were 90% and 94% respectively. For hypoxaemia, the sensitivity and specificity were 40% and 94% while for hyperoxaemia the sensitivity and specificity were 83% and 97%. We conclude that both machines provide a useful supplement to arterial PCO2 measurements and the Fastrac performs better at 43.0 degrees C. The measurement of PO2 is less accurate but is still of clinical use.
引用
收藏
页码:708 / 714
页数:7
相关论文
共 51 条
[1]  
Al-Siaidy W, 1979, Birth Defects Orig Artic Ser, V15, P149
[2]   GAS FLUX THROUGH HUMAN-SKIN - EFFECT OF TEMPERATURE, STRIPPING, AND INSPIRED TENSION [J].
BAUMGARDNER, JE ;
GRAVES, DJ ;
NEUFELD, GR ;
QUINN, JA .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (05) :1536-1545
[3]   MEASUREMENT OF TRANSCUTANEOUS CARBON-DIOXIDE IN LOW-BIRTH-WEIGHT INFANTS DURING THE FIRST 2 WEEKS OF LIFE [J].
BINDER, N ;
ATHERTON, H ;
THORKELSSON, T ;
HOATH, SB .
AMERICAN JOURNAL OF PERINATOLOGY, 1994, 11 (03) :237-241
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   EFFECT OF TEMPERATURE ON PCO2 AND PO2 OF BLOOD INVITRO [J].
BRADLEY, AF ;
STUPFEL, M ;
SEVERINGHAUS, JW .
JOURNAL OF APPLIED PHYSIOLOGY, 1956, 9 (02) :201-204
[6]   SKIN SURFACE PCO2 MONITORING IN NEWBORN-INFANTS IN SHOCK - EFFECT OF HYPOTENSION AND ELECTRODE TEMPERATURE [J].
BRUNSTLER, I ;
ENDERS, A ;
VERSMOLD, HT .
JOURNAL OF PEDIATRICS, 1982, 100 (03) :454-457
[7]  
BUCHER HU, 1986, PEDIATRICS, V78, P631
[8]  
BURNETT RW, 1974, CLIN CHEM, V20, P1499
[9]   FACTORS AFFECTING HEATED TRANS-CUTANEOUS PO2 AND UNHEATED TRANS-CUTANEOUS PO2 IN PRETERM INFANTS [J].
CABAL, L ;
HODGMAN, J ;
SIASSI, B ;
PLAJSTEK, C .
CRITICAL CARE MEDICINE, 1981, 9 (04) :298-304
[10]  
Fanconi S, 1987, Adv Exp Med Biol, V220, P159