EARLY RESULTS OF LUMBAR DUAL-ENERGY X-RAY ABSORPTIOMETRY (DEXA) COMPARED WITH DUAL-ENERGY QUANTITATIVE COMPUTER-TOMOGRAPHY (DE-QCT)

被引:4
作者
LINK, J [1 ]
ZWAAN, M [1 ]
WEISS, HD [1 ]
BORGIS, KJ [1 ]
BATGE, B [1 ]
机构
[1] MED UNIV LUBECK,INNERE MED KLIN,LUBECK,GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1993年 / 158卷 / 05期
关键词
BONE DENSITY MEASUREMENT; DE-QCT; DEXA;
D O I
10.1055/s-2008-1032685
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Bone density measurements were performed on 51 patients with suspected osteoporosis. We used DE-QCT and DEXA. The methods were compared with regard to deviation from normal. In 29 of the 51 patients there was more than half standard deviation and in 12 of the 51 cases there was more than a full standard deviation.
引用
收藏
页码:475 / 478
页数:4
相关论文
共 23 条
[1]  
BANZER D, 1989, ORTHOPADE, V18, P12
[2]   QUANTITATIVE CT FOR DETERMINATION OF BONE-MINERAL DENSITY - A REVIEW [J].
CANN, CE .
RADIOLOGY, 1988, 166 (02) :509-522
[3]  
DOREN M, 1988, RADIOLOGE, V28, P149
[4]  
Felsenberg D, 1988, Rofo, V148, P431, DOI 10.1055/s-2008-1048225
[5]  
FELSENBERG D, 1988, RADIOLOGE, V28, P166
[6]  
FELSENBERG D, 1991, ORTHOP PRAX, V27, P398
[7]   RATE OF SPINAL TRABECULAR BONE LOSS IN NORMAL PERIMENOPAUSAL WOMEN - CT MEASUREMENT [J].
FIROOZNIA, H ;
GOLIMBU, C ;
RAFII, M ;
SCHWARTZ, MS .
RADIOLOGY, 1986, 161 (03) :735-738
[8]  
FISCHER M, 1988, RADIOLOGE, V28, P179
[9]   APPROPRIATE USE OF BONE DENSITOMETRY [J].
GENANT, HK ;
BLOCK, JE ;
STEIGER, P ;
GLUEER, CC ;
ETTINGER, B ;
HARRIS, ST .
RADIOLOGY, 1989, 170 (03) :817-822
[10]  
HESCH RD, 1988, RADIOLOGE, V28, P143