COMPARISONS OF THE MEASURED AND CALCULATED SPECIFIC ABSORPTION-COEFFICIENTS FOR URBAN AEROSOL SAMPLES IN VIENNA

被引:37
作者
HITZENBERGER, R [1 ]
PUXBAUM, H [1 ]
机构
[1] INST ANALYT CHEM,A-1060 VIENNA,AUSTRIA
关键词
D O I
10.1080/02786829308959608
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Simultaneous measurements of the aerosol absorption coefficient sigma(a), using an integrating plate photometer, and of the mass size distribution of the aerosol between 0.06 and 16 mum in aerodynamic equivalent diameter, with a low-pressure Berner impactor, were conducted during a fairly stable period in April 1991. The size distributions were analyzed for total carbon (TC; i.e., the sum of organic and black carbon) by a combustion method; for SO42-, NO3-, Cl-, NH4+, Na+, and K+ by ion chromatography; and Ca and Mg by atomic absorption spectroscopy. This chemical analysis yielded nearly identical size distributions for SO42-, NO3-, and NH4+, with mean aerodynamic equivalent diameters typically approximately 0.7 mum. The ionic balance showed that the aerosol had been chemically neutral all the time. More than 70% of the accumulation mode mass was due to TC, SO42-, NO3-, and NH4+. The relative amount of internally and externally mixed carbon (with respect to the other accumulation mode species) was estimated. The externally mixed part of TC contributes up to 80% of TC mass for particles < 0.5 mum. The measured values of the specific absorption coefficient B(a) are compared to calculations of B(a) from chemical size distributions as functions of the black to total carbon ratios for three different mixing models. The measured values are always higher than the calculated ones, an effect that can be quantitatively explained by the calibration factor for the integrating plate photometer developed in Hitzenberger (1993). For the aerosol during this study, the overestimation of B(a) due to the integrating plate method lies in the range of 0.2-0.3 m2/g, which corresponds to approximately 20-30% of the true B(a). For less absorbing aerosols, the integrating plate photometer would give overestimations by 50% and for remote aerosols by 100%.
引用
收藏
页码:323 / 345
页数:23
相关论文
共 79 条
[1]   ABSORPTION OF VISIBLE RADIATION IN ATMOSPHERE CONTAINING MIXTURES OF ABSORBING AND NON-ABSORBING PARTICLES [J].
ACKERMAN, TP ;
TOON, OB .
APPLIED OPTICS, 1981, 20 (20) :3661-3668
[2]   CHARACTERISTICS OF SULFUR AEROSOL IN FLORIDA AS DETERMINED BY PIXE ANALYSIS [J].
AHLBERG, MS ;
LESLIE, ACD ;
WINCHESTER, JW .
ATMOSPHERIC ENVIRONMENT, 1978, 12 (1-3) :773-777
[3]  
Barber P.W., 1990, LIGHT SCATTERING PAR
[4]  
BAUMANN H, 1984, THESIS TU VIENNA
[5]   A CONCURRENT-FLOW CLOUD CHAMBER STUDY OF INCORPORATION OF BLACK CARBON INTO DROPLETS [J].
BENNER, WH ;
HANSEN, ADA ;
NOVAKOV, T .
AEROSOL SCIENCE AND TECHNOLOGY, 1989, 10 (01) :84-92
[6]   SIZE DISTRIBUTION OF TRAFFIC DERIVED AEROSOLS [J].
BERNER, A ;
REISCHL, G ;
PUXBAUM, H .
SCIENCE OF THE TOTAL ENVIRONMENT, 1984, 36 (JUN) :299-303
[7]  
BERNER A, 1984, AEROSOLS
[8]   SPECIFIC ABSORPTION OF A TINY ABSORBING PARTICLE EMBEDDED WITHIN A NONABSORBING PARTICLE [J].
BHANDARI, R .
APPLIED OPTICS, 1986, 25 (19) :3331-3333
[9]   DISTORTION OF SIZE DISTRIBUTIONS BY CONDENSATION AND EVAPORATION IN AEROSOL INSTRUMENTS [J].
BISWAS, P ;
JONES, CL ;
FLAGAN, RC .
AEROSOL SCIENCE AND TECHNOLOGY, 1987, 7 (02) :231-246
[10]  
BLANCHET JP, 1988, AEROSOLS CLIMATE