TECHNICAL REVIEW OF 100 MV POLARIZATION SHIFT CRITERION FOR REINFORCING STEEL IN CONCRETE

被引:17
作者
FUNAHASHI, M
BUSHMAN, JB
机构
[1] Corrpro Co Inc, Medina, OH
关键词
CATHODIC PROTECTION; CHLORIDE; CONCRETE; CORROSION RATE; IMPRESSED CURRENT; REINFORCING STEEL; TAFEL SLOPE; TEMPERATURE;
D O I
10.5006/1.3585268
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Criteria for effective cathodic protection of steel-reinforced concrete (SRC) structures presently in use were adopted from underground applications. Their applicability has been subject to considerable discussion. The two most frequently used criteria are the E log I and 100 mV polarization shift tests. To mitigate corrosion of reinforcing steel effectively, the use of valid cathodic protection criteria is extremely important. In this paper, an analysis of 100 mV polarization shift criteria for SRC is made based on the corrosion kinetics of steel in concrete and chemical and physical properties of concrete.
引用
收藏
页码:376 / 386
页数:11
相关论文
共 47 条
[1]  
ANDRADE C, 1984, STP, V906
[2]  
ARUP H, 1979, CORROSION79 134 PAP
[3]  
Arup H., 1979, ELECTROCHEMISTRY COR, V2, P8
[4]   CORROSION OF MILD-STEEL UNDER HEAT-TRANSFER IN HIGH-TEMPERATURE AERATED SODIUM-CHLORIDE SOLUTIONS [J].
ASHFORD, JH ;
GARNSEY, R ;
MANN, GMW .
CORROSION SCIENCE, 1974, 14 (09) :515-&
[5]  
BARLO TJ, 1984, CORROSION84 46 PAP
[6]   LINEAR CORROSION KINETICS [J].
BARNARTT, S .
CORROSION SCIENCE, 1969, 9 (03) :145-&
[7]  
BENNETT JE, 1989, CORROSION89 373 PAP
[8]  
BOCKRIS JO, 1975, MODERN ELECTROCHEMIS, V2
[9]  
CLEAR KC, 1987, MEASURING RATE CORRO
[10]  
DEHGHANIAN C, 1983, CORROSION, V39