SPECTROPHOTOMETRIC DETERMINATION OF MIXTURES OF 2-HYDROXYBENZALDEHYDE, 3-HYDROXYBENZALDEHYDE, AND 4-HYDROXYBENZALDEHYDE BY FLOW-INJECTION ANALYSIS AND UV/VIS PHOTODIODE-ARRAY DETECTION

被引:5
作者
NORGAARD, L [1 ]
RIDDER, C [1 ]
机构
[1] TECH UNIV DENMARK,CHEM DEPT A,BLDG 207,DK-2800 LYNGBY,DENMARK
关键词
D O I
10.1016/0039-9140(94)80168-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multivariate approach to the quantitative determination of 2-hydroxybenzaldehyde (salicylaldehyde), 3-hydroxybenzaldehyde, and 4-hydroxybenzaldehyde in their mixtures is described. The method is based on second order data generated in a flow injection analysis system with a pH gradient and photodiode-array detection. Each injection gave rise to an 89 (times) x 101 (wavelength) matrix, containing both the acidic and the basic characteristics of the sample injected. A least-squares algorithm based on Lambert-Beers law was used for the prediction of concentrations in unknown samples. No assumptions concerning the qualitative mixture composition of the hydroxybenzaldehydes were necessary to perform concentration predictions. The following four data types were used in the least-squares modelling: (1) unfolded raw data, (2) acidic spectra, (3) basic spectra, and (4) first spectral derivative of the raw data. The prediction errors obtained were comparable to literature results. A graphic method, based on the model residuals for detecting erroneous samples, was developed.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 16 条
[1]  
LUKKARI I, 1988, ANAL CHIM ACTA, V21, P1
[2]  
Martens H, 1989, MULTIVARIATE CALIBRA
[3]   SPECTROPHOTOMETRIC RESOLUTION OF TERNARY MIXTURES OF SALICYLALDEHYDE, 3-HYDROXYBENZALDEHYDE AND 4-HYDROXYBENZALDEHYDE BY THE DERIVATIVE RATIO SPECTRUM-ZERO CROSSING METHOD [J].
NEVADO, JJB ;
CABANILLAS, CG ;
SALINAS, F .
TALANTA, 1992, 39 (05) :547-553
[4]   RESOLUTION OF THE BINARY MIXTURE OF SALICYLALDEHYDE AND 4-HYDROXYBENZALDEHYDE BY USING 1ST DERIVATIVE RATIO SPECTRA [J].
NEVADO, JJB ;
CABANILLAS, CG ;
LOPEZ, FS .
ANALYTICAL LETTERS, 1990, 23 (11) :2077-2094
[5]  
NEVADO JJB, 1991, B SOC CHIM BELG, V100, P79
[6]   DETERMINATION OF PH GRADIENTS AND ACIDITY CONSTANTS IN FLOW-INJECTION ANALYSIS SYSTEMS BY EVOLVING FACTOR-ANALYSIS [J].
NORGAARD, L .
ANALYTICA CHIMICA ACTA, 1991, 255 (01) :143-148
[7]  
NORGAARD L, 1993, UNPUB 3RD P SCAND S
[8]   NUMERICAL ERROR ANALYSIS OF DERIVATIVE SPECTROMETRY FOR QUANTITATIVE-ANALYSIS OF MIXTURES [J].
OHAVER, TC ;
GREEN, GL .
ANALYTICAL CHEMISTRY, 1976, 48 (02) :312-318
[9]  
OHAVER TC, 1979, CLIN CHEM, V25, P1548
[10]  
Perrin D.D., 1974, BUFFERS PH METAL ION