SALT EFFECTS IN ANION-EXCHANGE DISPLACEMENT CHROMATOGRAPHY - COMPARISON OF PENTOSAN POLYSULFATE AND DEXTRAN SULFATE DISPLACERS

被引:26
作者
GADAM, SD [1 ]
CRAMER, SM [1 ]
机构
[1] RENSSELAER POLYTECH INST,ISERMANN DEPT CHEM ENGN,TROY,NY 12180
关键词
COLUMN LIQUID CHROMATOGRAPHY; ION-EXCHANGE CHROMATOGRAPHY; PROTEIN PURIFICATION; PENTOSAN POLYSULFATE DISPLACERS; DEXTRAN SULFATE DISPLACERS;
D O I
10.1007/BF02278755
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Experimental studies were carried out to investigate the utility of pentosan polysulfate as a low molecular weight polyelectrolyte displacer for the purification of proteins in anion-exchange displacement systems. In addition, the influence of mobile phase salt concentration on displacer efficacy, protein-protein resolution, and displacement development were studied for several anionic displacers. It was found that while large polyelectrolytes (50 kd dextran sulfate) were efficient displacers for a wide range of salt concentrations, relatively small polyelectrolytes (3 kd pentosan polysulfate) were seen to act as an efficient displacer only under conditions of high salt micro-environments. In addition, for proteins exhibiting similar affinities, zone mixing at the protein-protein boundary was found to be quite sensitive to the salt concentration. Finally, displacement chromatography was successfully implemented for the separation of proteins from milk whey.
引用
收藏
页码:409 / 418
页数:10
相关论文
共 26 条
[1]   STERIC MASS-ACTION ION-EXCHANGE - DISPLACEMENT PROFILES AND INDUCED SALT GRADIENTS [J].
BROOKS, CA ;
CRAMER, SM .
AICHE JOURNAL, 1992, 38 (12) :1969-1978
[2]  
BROOKS CA, 1994, UNPUB CHEM ENG SCI
[3]   RECENT ADVANCES IN THE THEORY AND PRACTICE OF DISPLACEMENT CHROMATOGRAPHY [J].
CRAMER, SM ;
SUBRAMANIAN, G .
SEPARATION AND PURIFICATION METHODS, 1990, 19 (01) :31-91
[4]   INVESTIGATION OF OPERATING PARAMETERS IN HIGH-PERFORMANCE DISPLACEMENT CHROMATOGRAPHY [J].
FRENZ, J ;
VANDERSCHRIECK, P ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1985, 330 (01) :1-17
[5]  
FRENZ J, 1988, HIGH PERFORMANCE LIQ, V5, P211
[6]   CHARACTERIZATION OF NONLINEAR ADSORPTION PROPERTIES OF DEXTRAN-BASED POLYELECTROLYTE DISPLACERS IN ION-EXCHANGE SYSTEMS [J].
GADAM, SD ;
JAYARAMAN, G ;
CRAMER, SM .
JOURNAL OF CHROMATOGRAPHY, 1993, 630 (1-2) :37-52
[7]  
GADAM SD, 1994, IN PRESS AICHE J MAY
[8]   CATION-EXCHANGE DISPLACEMENT CHROMATOGRAPHY OF PROTEINS WITH PROTAMINE DISPLACERS - EFFECT OF INDUCED SALT GRADIENTS [J].
GERSTNER, JA ;
CRAMER, SM .
BIOTECHNOLOGY PROGRESS, 1992, 8 (06) :540-545
[9]  
GERSTNER JA, 1992, BIOPHARM, V11, P42
[10]   EVALUATION OF DISPLACEMENT CHROMATOGRAPHY FOR THE RECOVERY OF LACTATE-DEHYDROGENASE FROM BEEF-HEART UNDER SCALE-UP CONDITIONS [J].
GHOSE, S ;
MATTIASSON, B .
JOURNAL OF CHROMATOGRAPHY, 1991, 547 (1-2) :145-153